5-3 TRANSMITTER ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITION
YGR
1 • Preset R1086 and R1087 maxi-
CURRENT
mum counterclockwise.
[ FPGA D.C.
• Preset "IQ Direct-current output"
voltage ad-
ON.
justment
• Operating freq. : 1300.00 MHz
2
/DV I ]
• Mode
• Connect an RF power meter or
50 Ω dummy load to the antenna
connector.
• Transmitting
REFERENCE
1 • Operating freq. : 1300.00 MHz
FREQUENCY
• Mode
[ REF Crystal
• Connect an RF power meter or
50 Ω dummy load to the antenna
adjustment]
connector.
• Transmitting
FM
1 • Operating freq. : 1300.00 MHz
CARRIER
• Mode
[ FPGA D.C.
• Connect an RF power meter or
50 Ω dummy load to the antenna
voltage ad-
justment
connector.
/FM I]
• Transmitting
[ FPGA D.C.
2 • Transmitting
voltage ad-
justment
/FM Q]
OUTPUT
1 • Operating freq. : 1300.00 MHz
POWER
• Mode
[ TX output
• TX power
adjustment]
• Transmitting
FM
1 • Operating freq. : 1270.00 MHz
DEVIATION
• Mode
[ FM
• Connect an audio generator to
modulation
the [MIC] connector and set as
adjustment]
• Set a Modulation analyzer as:
HPF
LPF
De-emphasis : OFF
Detector
• Transmitting
DSP INPUT
1 • Operating freq. : 1270.00 MHz
LEVEL
• Connect an audio generator to
[ D S P i n p u t
the [MIC] connector and set as
level adjust-
ment]
• Connect an RF power meter or
50 Ω dummy load to the antenna
connector.
• Transmitting
UNIT
Rear
panel
: DV mode
Rear
: FM mode
panel
MAIN
: FM mode
unit
Rear
: FM mode
panel
: High
Rear
: FM mode
panel
: 1.0 kHz/20 mVrms
: OFF
: 20 kHz
: (P–P)/2
LOGIC-1
unit
: 1.0 kHz/20 mVrms
5 - 5
MEASUREMENT
LOCATION
Connect an ammeter
between the DC power
supply and ID-1.
Loosely couple a fre-
quency counter to the
antenna connector.
C o n n e c t a d i g i t a l
multimeter or an oscillo-
scope to the check point
"CP30".
Connect an RF power
meter to the antenna
connector.
Connect a modulation
analyzer to the antenna
connector through an
attenuator.
C o n n e c t a n o s c i l l o -
scope to the check point
"CP207".
ADJUSTMENT
VALUE
UNIT
ADJUST
100 mA higher
MAIN
from the pre-
unit
set position.
100 mA higher
MAIN
from step 1.
unit
1300.0000 MHz
PC
[ REF
screen
T h e s a m e
PC
[ FPGA
vo l t a g e t h a t
screen
during in DV
m o d e ( T X )
at the check
point "CP30".
T h e s a m e
PC
[ FPGA
adjustment as
screen
step 1, if need.
11 W
MAIN
unit
±4.35 kHz
MAIN
unit
750 mVp-p
MAIN
unit
R1087
R1086
Crystal
adjust-
ment]
D.C.
voltage
adjust-
ment
/FM I]
D.C.
voltage
adjust-
ment
/FM Q]
R1251
R1704
R1707