5-4 RECEIVER ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITIONS
RECEIVER
1
• Operating frequency : 136.000 MHz
SENSITIVITY
• Connect an SSG to the antenna con-
nector and set as:
Level
Modulation : OFF
• Connect a 4 Ω load to the external
speaker jack.
• Enter Initial Set Mode No. 5.
Refer to page 5-2 for details.
• Receiving
NOISE
1
• Make sure no signal is being applied
SQUELCH
to the antenna connector.
• Enter Initial Set Mode No. 2.
THRESHOLD
POINT
Refer to page 5-2 for details.
• Operating frequency : 136.000 MHz
• Receiving
2
• Connect an SSG to the antenna con-
nector and set as:
Level
Deviation
Modulation : 1 kHz
• Receiving
BEEP
1
• Enter Initial Set Mode No. 3.
LEVEL
Refer to page 5-2 for details.
• Operating frequency : Any
• Receiving
*This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
• MAIN UNIT
Number digits in the LCD
: 5.6 µV* (–92 dBm)
Speaker output
: 0.25 µV* (–119 dBm)
: ±3.5 kHz
Speaker output
5 - 4
MEASUREMENT
METHOD
Maximum indi-
cation
At
where the noise
audio just disap-
pears.
Squelch opens
ADJUSTMENT
VALUE
ADJUST
Adjust in
sequence
L8, L11, L12, L13
on the MAIN unit
the
point
Rotate volume
control while
pushing
P
Verify
Desired level
Rotate volume
control while
pushing
P
L8
Receiver
L11
sensitivity
L12
adjustment
L13
2
3

Hide quick links: