Advertisement

About this IR Camera User Guide
Symbols Used
This mark denotes issues that may affect the IR camera's operation.
This mark denotes additional topics that complement the basic
operation procedures.
 What do the icons listed in the Camera User Guide mean?
Information displayed on the LCD Monitor (p.18)
TrademarkAcknowledgments
• SDSistrademarksofSDSLTD..
Microsoft,WindowsandWindowslogoiseitherregisteredtrademarksortradema
rksofMicrosoftCorporationintheUnitedStatesand/orothercountries.
Othernamesandproductsnotmentionedabovemayberegisteredtrademarksor
trademarks oftheirrespectivecompanies.
Copyright©2009SDSLTD. Allrightsreserved.
Quality SATIR Products Online at:
GlobalTestSupply
www.
1
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E8-N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Satir E8-N

  • Page 1  What do the icons listed in the Camera User Guide mean? Information displayed on the LCD Monitor (p.18) TrademarkAcknowledgments • SDSistrademarksofSDSLTD.. • Microsoft,WindowsandWindowslogoiseitherregisteredtrademarksortradema rksofMicrosoftCorporationintheUnitedStatesand/orothercountries. • Othernamesandproductsnotmentionedabovemayberegisteredtrademarksor trademarks oftheirrespectivecompanies. Copyright©2009SDSLTD. Allrightsreserved. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 2 Explains how toreview recorded images, erase Playback and images and playback voice memos. erase Explains how totransfer images or video to a Connection computer. and download Youmust readthis sectionbefore connectingyour camera to a computer. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 3: Table Of Contents

    Focus. ………………………………..………………………… Manual Focus…………….………………………………… Display Modes….……………………………………………… DuoVisionDisplay modes …………………………….….. DuoVision…………………………………………………… Image Adjustment………………………………………….….. Auto Adjust……..…………………………………………… Manual Adjustment………………………………………… Palette settings……………………………………………... Image Settings…………………………………………..……... Measurement Range………………….……………………….. Freezing/ Activating an Image.……………………………….. Fulfill the Analysis Function…………………….……………..… Object/Global Settings….……….……………….….………..GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 4 Transfer Video via USB………...………..…………………. Troubles shooting…..…………………………………….…. Use the Bluetooth headset…………………………………. Accessory…………………………………………………… Use the sun shield………………………………………………… Use the optional lens……………………………………………… Troubles Shooting……………………….…………………. 71 Appendix………………………………………………….…. Camera Care and Maintenance………………….…………….. Emissivity table…………………………………………………… Specifications…………………………….…….…………… 79 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 5: Read This First

    Read This First Please Read Test Shots Beforeyoutryto shootimportantsubjects,wehighly recommendthatyoushootseveraltrialimagestoconfirmthatthe cameraisoperatingandbeingoperatedcorrectly. PleasenotethatSDS,itssubsidiariesandaffiliates,andits distributorsarenotliableforanyconsequentialdamagesarising fromanymalfunctionofan cameraoraccessorythatresultsinthefailureofanimagetobe recordedortoberecordedinaformatthatismachinereadable. WarningAgainstCopyrightInfringement Safety Precautions Beforeusingthecamera,pleaseensurethatyoureadand understandthesafetyprecautionsdescribedbelow.Always ensurethattheIR cameraisoperatedcorrectly. Thesafetyprecautionsnotedonthefollowingpagesareintended toinstructyouinthesafeandcorrectoperationoftheIR cameraand itsaccessoriestopreventinjuriesordamagetoyourself,other personsandequipment. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 6 In dust, humid or greasy environments, the dust that collects around the plug over long periods of time may become saturated with humidity and short-circuit, leading to fire. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 7 It could lead to leakage and injury. Do not short-circuit the battery terminals with metallic objects, such as key holders It could lead to overheating, burns and other injuries. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 8 If your camera is used for prolong periods, the IR camera body may become warm Please take care when operating the IR camera for an extended period as your hands may experience a burning sensation. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 9 Storing the IR camera for extended periods with battery installed will run down the battery. Different Models Some advanced functions are included only in E8-TN and E8-GN, E8-N only has the fundamental function Right Reserved SDSreserves the right to change the functions and configurations of our products without prior notice.
  • Page 10: Component Guide

    Front View *Illuminator Lens Locking *Visual CCD Ring Camera *Laser Pointer Thermal Lens Focus Ring Definable Trigger Multi-function Dock *E8-N is not equipped with illuminator, visual CCD camera and laser pointer. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 11: Back/ Bottom View

    Component Guide Back / Bottom View LCD Display Key Pad USB Terminal Video out Terminal Battery /SD Card Cover GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 12 Component Guide Controls / Multi-function Dock Auto Adjust Key Power Switch Power Indicator Freeze / Activate Cancel Key Menu / Enter Key Cursor Key Terminal Power Terminal Video Output Terminal GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 13: Bottom/Connectors

    Component Guide Bottom / Connectors Multi connector SD Card Slot Battery Lock Battery insertion slot Lock Multi connector GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 14: Preparing The Ir Camera

    (battery life), you are recommended to only charge the battery pack after having discharge it completely to prolong battery life. • Charging times will vary according to the surrounding humidity and battery pack charge state. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 15: Installing The Battery Pack/ Sd Card

    Insert the battery pack. Insert battery direction of the arrow. Insert SD card. Insert the SD card in the direction of the arrow. Close the battery / SD card cover. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 16 The SD Card must be formatted in FAT32. Otherwise, the IR camera may not recognize the SD card. Battery Status Symbols The following icons indicate the battery status on the LCD display. Sufficient battery charge Low battery Replace or recharge the battery GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 17: Turning The Power On/ Off

    The power indicator lights green. After a while, a startup image will appear on the screen. Turn off the camera. Hold the power switch for 3 seconds. • The power indicator goes off. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 18: Checking The Information

    Lower limit of color scale Time Min. temperature Battery Charge Activate Current / Freeze Emissivity Operation indicator About the operation indicator The operation indicator shows the current operation status of the camera. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 19 *The status varies according to different model of E8 series. Before you make any further operation, please enter [Null] mode. How to enter [Null] mode: Press the cancel key repeatedly until see the message of null in the operation indicator. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 20: Setting The Date/ Time

    After adjusting the settings, press the MENU/ ENTERkey to save changes, or press the C key to go back to upper menu without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 21: Local Settings

    Press the LEFT or RIGHT arrow on the omni selector to set the values. After adjusting the settings, press the Menu/ Enter key to save changes, or press the C key to exit without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 22 Sets the format of the displayed temperature unit Temp unit of the camera. °C or °F. Distance Sets the format of the displayed distance unit of unit the camera. Meter or Foot. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 23: Basic Functions

    1. For a better temperature measurement, please do make the subject in center of the image that is shown on the LCD monitor. 2. The LCD monitor will turn off when it is closed. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 24: Selecting Menus And Settings

    Press the UP or DOWN arrow on the omni selector. Press the MENU / ENTER button. Menu Select a function item using Analysis Menu File Menu Manual Adjust Setup Menu GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 25 Select setting contents using Change the settings using Exit Displayed menu items will vary according to the operation and setting contents. *The menu items are different according to different type of camera. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 26: Resetting The Setting To Default

    Press and hold the power switch and C key for seconds. Cancel key The data in storage will not be deleted when you reset the menu and button operation settings to default. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 27: Shooting

    IR Camera Adjustment Manually Focus Aim that the IR camera at the subject. Turn the focus ring to focus on the target. Do not stop turning until the image is clear. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 28: Duovisiondisplay Modes

    [Mode],and press LEFT or RIGHTto select a display mode, then press MENU/ENTER key. *E8-N is not equipped with a visual CCD camera and it doesn’t have the DuoVision Display modes, so you won’t see the [IR/Visible] item in its menu.
  • Page 29: Duovision

    And the thermal image “fuses” on it in the center square. At the same time you can use any analysis tools to analyze the target. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 30 Move the area right C + LEFT C + RIGHT About the IR/Visible settings Sets the ratio of IR images and Visual images. The Percentage value is from 1% to 100%. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 31 The items above are activated only in [Duo-Vision] mode. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 32: Image Adjustment

    A key for the first time. If you press A key a second time in 15 seconds, the camera will only adjust brightness and / or contrast. You can define the adjustment mode,p.34. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 33 After this operation, press the MENU/ENTER key to save changes, or press the C key to go back to the upper menu without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 34: Palette Settings

    After this operation, press the MENU/ENTER key to save changes, or press the C key close the menu without saving. The camera provides 6 kinds of palettes: Iron, Iron inverted, Rainbow, Feather, Grey and Grey inverted. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 35: Image Settings

    After this operation, press the MENU/ENTER key to save changes, or press the C key to go back to the upper menu without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 36 Sets the period of shutting down the LCD Display. Shut Down Sets the perid of shutting down the camera. Laser Adjust Adjusts the Laser point in the LCD displayer. Menu Style Sets the menu style. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 37: Measurement Range

    After this operation, press the MENU/ENTERkey to save the changes or press the C key to go back to the upper menu without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 38: Freezing/ Activating An Image

    Check that the IR camera is in null mode.(p.19) Press the S key, then the image is freezing. Press the S key again, then the image is active. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 39: Fulfill The Analysis Function

    Setting analysis parameter. • Press the UP or DOWN arrow on theomni selector to select anitem to change. • Press the LEFT or RIGHT arrow on the omni selector to set the values. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 40 For example, Comp Obj1 is Spot1(35.4℃) and Comp Obj2 is Ref Temp(30℃),then the final reading will be 5.4℃. Sets a reference temperature to compare Ref Temp with the spot/area/profile tool. The reading of Comp. Obj GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 41 Reading GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 42: Analysis Settings

    Press the LEFT or RIGHT arrow on the omni selector to set the values. After this operation, press the MENU/ENTERkey to save changes, or press the C key to go back to the upper menu without saving. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 43 0.1℃ to the upper limit of the Width maximum temperature measurement range under this condition. *Isotherm Sets the color of the isotherm interval. Transparent, Color Green, Black and White are available. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 44 35℃ to 40℃ and the isotherm alert is Alert 100. If the proportion of isotherm area between 35℃ to 40℃ is over 100/255, alarm will ring. *Temperature alert and isotherm settings are only for E8-TN and E8-GN. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 45: Setting Analysis Tools

    Spot 10 will automatically track the hottest and coldest temperature spot withinan area of which the shape and size can be set by the user(p.46). Press LEFT or RIGHTto select the Maximum spot or Minimum spot. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 46 Start from Step 1 to set or select an analysis spot. • Press C key to remove the spot. *E8-N has only one analysis spot; E8-TN has four analysis spots. The menu showed in the photo of step 4 is different according to different models. GlobalTestSupply www.
  • Page 47: Area Analysis

    H is short for highest temperature, L for lowest temperature, and A for average temperature. • Press LEFT or RIGHTto select to show the Maximumor Minimum or Average temperature of the area. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 48 Start from Step 1 to set or select an area analysis. • Press C key to remove the activated area. About changing the shape of the analysis area UPPER and RIGHT arrow UPPER and LEFT arrow GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 49 LOWER and LEFT arrow LOWER and RIGHT arrow *E8-N and E8-TN don’t have the area analysis function, so you won’t see the [Area] item in their analysis menu. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 50: Profile Analysis

    Start from Step 1 to set or select a profile analysis. • Press C key to remove the activated profile. *E8-N and E8-TN don’t have the profile function, so you won’t see the [Profile] item in their analysis menu. GlobalTestSupply www.
  • Page 51: Isotherm Analysis

    It is the high limit (IH) and low limit (IL) of the isotherm range. To change isotherm type, isotherm width, isotherm alert and highlight color,see p.41. *E8-N doesn’t have the isotherm analysis function, so you won’t see the GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 52: Remove Analysis Tools

    Press the MENU/ENTER key to remove all the spots. You can also delete a single analysis tool by pressing C key after selecting the analysis tool. Please seep43,p45,p46. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 53: Saving Image

    The display mode decides the save image type.(p.28) The name of saving image will be displayed on the screen. The image will be saved in the current folder, p.55. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 54: Attaching Memos To Images

    Speak toward the microphone of the headset. To stop recording, press the C key. Save the image (p.50). The storage capacity of the memory will not decrease when you attach voice comment to an image. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 55 Do not trigger the laser pointer in human or animal eyes.Exposure to the laser produced by the laser pointer may damage eyesight. Freeze/Live Freeze or activate an image. Auto adjust Automatically adjust the brightness and contrast. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 56 *E8-N is not equipped with laser and illuminator GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 57: Playback And Erase

    You can analyze and attach voice memo to a recorded image when you open it. You can press the A, C and S key together to set the folder name to sat00001. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 58 If the image you wish to open or delete is not in the current folder, press the [LEFT] or [RIGHT]arrow on the omni selector repeatlyto select the image. Press the S key, you can activate the image. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 59 Press the UPorDOWN arrow on the omni selector to select the [File Name] menu, then press the LEFTorRIGHT arrow to select the filename. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 60: Playback Memos

    Play], then press the Menu/Enter key. • A [Playing Record] message will appear on the LCD monitor. You can terminate the playback of voice comment by pressing theC key. *Bluetooth is only for E8-GN GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 61 Press UPorDOWN arrow on the omni selector to select [Delete], then press the MENU/ENTER key. Select an image,refer to(p.54), then press MENU/ENTER key to delete the selected image. Press the C key to exit. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 62: Download The Images

    Open the battery / SD card cover. Press the SD card lightly, then the SD card will pop-up automatically. You can download the IR images via the supplied SD card reader. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 63: Connecting And Download

    Press the camera gently down to the dock in the direction of the flute in the dock. Now you can use the multi-functional dock. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 64: Charging Via The Dock

    • The power LED of camera flickers while the battery pack is charging and it lights green when charging is complete. • Unplug the power adaptor from the power outlet,after charging. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 65: Connecting To A Monitor

    Attach video cable to the video out terminal on the multi-functional dock. Plug the other end of the video To the cable to the video in jack on the video in jack monitor. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 66: Connecting To A Computer

    • Please refer to your computer manual for information regarding the location of the USB port USB PORT DOCK USB CABLE The USB port can only be used with optional real-time software. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 67: Installing Driver

    After a few moments, the following dialog will appear. Select [No, not this time] then click [Next >]. Select [Install from a list or location (Advanced)] then click [Next >]. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 68 [browse]. Locate the directory of the driver, and click [Ok] to return to the previous window. Then click [Next > Click [Continue Anyway]. Click [Finish] to finish the driver installation. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 69: Transfer Video Via Usb

    Connect the dock and computer via USB cable (optional), p.62. The operation system will recognize the camera after install the driver, p.61. You can analyze the real-time video, and save it in your computer’s disk. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 70: Troubles Shooting

    The USB2.0 real-time transmission function may not properly work under some model of motherboard’s chipset. In this case, connect the IR camera to another computer which is based on the chipset of Intel configuration or NVidia configuration and try again. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 71: Use The Bluetooth Headset

    Make sure that the camera is not too far from the Bluetooth headset.If possible, try to take the Bluetooth headset closer to the camerain step 4. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 72 Wear the headset, you can record the vioce memos (p.51) or play back the memos (p.56) now. *Bluetooth headset is not the standard accessory of E8-N and E8-TN. The picture is for reference and the sample is subject to the real product which you will receive.
  • Page 73: Accessory

    Use the sun shield You will see more clearly with sun shield when you are shooting outdoors in the sun. Install the sun shield inthe direction of the arrow by followintg the below guide. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 74: Use The Optional Lens

    (p.36). Refer to the below table to see what type of lens the letterstands for. Type Null Lens 20° 12.8° 38° 3.8° 6.4° 9° GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 75: Troubles Shooting

    • Connect the power cord to the charge charger. battery charger and insert its plug firmly into the power outlet. • Replace the battery pack with a Battery life exceeded new one. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 76: Appendix

    Never rub or press forcefully on the LCD monitor. These actions may damage it or lead to other problems. Never use thinners, benzene, synthetic cleaners or water to clean the camera. These substances may distort or damage the equipment. GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 77: Emissivity Table

    Brass oxide 200~600 0.61~0.59 Chrome Polished chrome 40~1090 0.08~0.36 Copper Copper mirror 0.05 Strong copper oxide 0.078 Cuprous oxide 800~1100 0.66~0.54 Liquid copper 1080~1280 0.16~0.13 Gold Gold mirror 0.02 230~630 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 78 Cast iron, heavy ferric 0.80 oxide Tempered iron, ferric 0.95 40~250 oxide Melting surface 0.94 Melting cast iron 1300~1400 0.29 Melting mild steel 1600~1800 0.28 Liquid steel 1500~1650 0.42~0.53 Pure liquid iron 1515~1680 0.42~0.45 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 79 0.37~0.48 Nickel oxide 650~1255 0.59~0.86 Nickel alloy Nickel-chrome (heat- resistance) alloy wire 50~1000 0.65~0.79 (shining) Nickel-chrome alloy 50~1040 0.64~0.76 Nickel-chrome (heat 50~500 0.95~0.98 resistance) Nickel-silver alloy 0.14 Silver Polished silver 0.05 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 80 Non-metal materials Brick 1100 0.75 Fire brick 1100 0.75 Graphite (lamp black) 0.95 96~225 Porcelain enamel 0.90 (white) Asphaltum 0.85 0~200 Glass (surface) 0.94 Heat-resistance glass 200~540 0.85~0.95 Calcimine 0.90 0.90 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 81 Film 0.90~0.93 Mica 0.94~0.95 Flume mica 0.90~0.93 Glass 0.91~0.92 Semiconductor 0.80~0.90 Transistor (plastics 0.30~0.40 sealed) Transistor (metal) 0.89~0.90 Diode Transmitting loop Pulse transmission 0.91~0.92 Level chalkiness layer 0.88~0.93 Top loop 0.91~0.92 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 82 Material Temperature(°C) approximation Electric materials Epoxy glass plate 0.86 Epoxy 0.80 hydroxybenzene plate Gilded sheet copper 0.30 Solder-coated copper 0.35 Tin-coated lead wire 0.28 Brass wires 0.87~0.88 Block talcum terminal 0.87 GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 83: Specifications

    /Analysis tools isotherm, Δt spot,profile, area spot,Δt box, isotherm, Δt Temperature Alarms Set-up Controls Language/Date And Time Format/Palettes/Units Measurement Ambient Temperature/EmissivityCorrection/ Corrections Distance/ Humidity GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...
  • Page 84 USB (Cable included) Video Output NTSC/PAL Bluetooth Earphone Tripod mounting 1/4”_20 Software SatIrReport Standard Version Optional Lens 38 degree wide angle Lens 12 degree Lens 6 degree lens 3.8 degree lens GlobalTestSupply www. .com Quality SATIR Products Online at: sales@GlobalTestSupply.com...

This manual is also suitable for:

E8-tnE8-gn

Table of Contents