Satir CK350-F User Manual

Satir CK350-F User Manual

Fever screening system

Advertisement

Quick Links

Privacy & Terms:
Our privacy and security principles
SATIR committed to creating privacy protection technology for everyone. When developing products and services to our customers, every effort must be made to protect user privacy. This becomes even more important as technology advances
and the need for privacy protection continues to rise.
1. Respect users and their privacy.
SATIR believe that these ideas are complementary and indivisible. When people use our products, they show that they trust us in how we handle their information, and we must do our best to live up to their trust. This means that we always
exercise caution when deciding what data to use, how to use it, and how to protect it.
2. SATIR products will never collect customer's data.
3. SATIR will never sell your personal or company information to anyone.
4. Give users easy control over their privacy protection settings.
In terms of privacy protection, uniform settings are bound to not meet the needs of all users, so we provide data controls in SATIR software so that users can turn them on or off by themselves to choose the privacy protection settings that suit
them. With the continuous development of technology, our privacy control settings are also constantly being improved to ensure that privacy protection settings are always selected by users.
5. The most powerful security technology built into our products.
Respecting the privacy of users means protecting the data that users provide to us based on trust. To ensure that all SATIR products and services are safe for users, we develop and implement the most advanced security infrastructure in the
world.
GDPR: New EU regulation defines the handling of customer data
On 28 May 2018, the new General Data Protection Regulation (GDPR) will become effective. On one hand, the new set of rules determines how companies must protect personal data and on the other hand, how the free flow of data should
be regulated.
GDPR supersedes the previous data protection directive (95/46/EC) from 1995. The protection of personal data was already anchored in the existing directive; but the requirements for companies were less strict. In comparison to other countries,
data protection already has a particularly high significance in Germany and Switzerland. Even for companies which have implemented the "Federal Data Protection Act", urgent action is needed, as even minor changes to the regulations
frequently mean that adjustments must be made to organizational processes, products, documentation obligation and IT. Existing contracts in B2B and B2C contexts must also be checked regarding GDPR and amended if necessary.
SATIR CK350-F Fever Screening System provides facial recognition functions and is the key function of the system when performing the fever screening feature, it's purpose is for medical workers or operators to control or identify a potential
high fever person, it's purpose is not for data collection but a tool for quarantine applications.
A clear visible sign should be provided along with the camera, for people who entering the camera's measuring zone, their facial info with temperature data will be scan. There is a responsibility on the end-user of the CK350-F to put up a
clear visible sign notifying people that their faces and body temperature are being recorded for fever screening purposes.

Advertisement

Table of Contents
loading

Summary of Contents for Satir CK350-F

  • Page 1 Respecting the privacy of users means protecting the data that users provide to us based on trust. To ensure that all SATIR products and services are safe for users, we develop and implement the most advanced security infrastructure in the...
  • Page 2 SATIR CK350-F Fever Screening System User Manual ©SATIR 2020 all right reserved.
  • Page 3 1. Camera Installation Guide In Door:...
  • Page 4 Outdoor: (If outdoor temperature not exceed 10℃ to 25℃(50 °F to 77°F), a shelter may not require for using the system. But the camera must out of direct to any heat targets, e.g. sun, car, power generator and avoid strong winds, rain etc.)
  • Page 5: Working Environment

    Working Environment Camera and blackbody must install at indoor environment or cover with tent/shelter. Working ambient temperature should not exceed 0℃ to 30℃ (32 °F to 86°F). Keep the camera and optics out of direct sunlight, wind, rain or other sources of heat objects.
  • Page 6 Camera body Dimensions(mm)
  • Page 7 Wall Bracket (Optional) Dimensions(mm)
  • Page 8 Ceiling Bracket (Optional) Camera Blackbody Dimensions(mm)
  • Page 9: Cable Connection

    Cable Connection Core of Cable Functions Code of Cable Functions RS485 interface connects to the external pan & tilt. Connects to the external audio device such as the voice box. RS485 Audio Output Power interface, connects to the 12 V DC power adapter, DC12V (2A) ALARM IN2 110V to 240V power source.
  • Page 10 2. IP Camera Setting up. Please use Windows Internet Explorer Browser ONLY, NO Microsoft edge/Google Chrome/Firefox etc. browser!!! 192.168.0.121 2.1 Change Windows 10 IP address to match the camera’s IP address. Camera default IP: I Click on ‘Network and Internet’ and then on ‘Network and sharing center’ II Click on ‘Change adapter settings’...
  • Page 11 2.2 Camera set up on Browser (Internet Explorer), Open IE browser, enter IP address: 192.168.0.121, IP Camera default Username: admin, Password: admin Change the password only if needed, not recommend change at first time Install Plugin:...
  • Page 12 2.3 Configuration Make sure you can see the images, go to the Configuration>Human Thermometer>Parameter Configure>Turn on Face Detection>Turn on Area Detection>Clear Detection Area,...
  • Page 14 New Detection Area 2.3.1 Draw a based on the installation environment. Apply!
  • Page 15 2.3.2 Alarm Temperature set up on IP camera. Select Face Alarm Linkage>set the Alarm Temperature (Please make sure the alarm temperature is set to the same at Fever Screening Software-Normal Temperature)
  • Page 16 2.3.3 Thermal Mapping for accurate temperature reading and facial recognition (VERY IMPORTANT). Step 1: Adjust zoom and focus on the visible lens. The angle of view should be similar to the thermal view. Step 2: Select Mapping point (Point One, Point Two, Point...
  • Page 18 2.3.4 Blackbody Calibration Select Thermal Calibration>Enable>Display Area Info-Enable Draw a small square (size smaller than the blackbody) at the center of the Blackbody as a reference source for the camera, Apply!
  • Page 19 2.3.5 Close the browser after the above settings. DO NOT CHANGE ANY OTHER SETTINGS IF YOU ARE NOT SURE ABOUT THE FUNCTIONS. ANY OTHER CHANGES MAY AFFECT THE CORRECT TEMPERATURE MEASUREMENT!!! Please contact SATIR technical support team if you have any doubts!
  • Page 20 3 Software Installation & Settings Install the Fever Screening Software on Windows 10. Computer Recommend Configurations: Processor (CPU): Intel Core i5 (sixth generation or newer) or equivalent, Memory:8 GB RAM, Storage:500 GB SSD internal storage drive Or better computer for the best performance of the system.
  • Page 21: Software Setting

    3.1 Software Setting 3.1.1 Log in to software: default username: admin, default password: admin, the username and password is auto input at the first time of software installation. Username and password can be change on the software.
  • Page 22 3.1.2 Operation Interface First time login to the Interface, please select Devices...
  • Page 23 3.1.3 Add device Select Auto Search>Start Search>Select>Model CK350-F>Add (Note: Username and Password must be the same as the IP Camera on web browser)
  • Page 24 3.1.4 Enter the Control Interface Back to Main Menu> Select Face Recognition Enter the Face Recognition interface...
  • Page 25 3.1.5 Software Operation Select device, CK350-F CH1-Visual Camera, CK350-F CH2 Thermal Camera, DOUBLE click Select, enter the camera. Screen can show both Visual and Thermal at the same time. Recommend use Visual Camera only.
  • Page 27 3.1.6 User Interface Real-time face recognition and temperature data When alarm target detected, the square will turn to RED, face temperature and info will be capture. If the square is Blue, it means the target is not in the measurement area. 3.1.7...
  • Page 28 Alarm temperature setting. Go back to Main Menu> Select Alarm Temperature...
  • Page 29 3.1.8 Alarm Temperature setting 36.0℃ to 37.3 ℃ 37.3 ℃, Standard Normal Body temperature default set to , we recommend the Alarm temperature set to 37.3 ℃, a further Medical Mercury thermometer temperature check or quarantine action Anyone detect temperature over should be carrying out.
  • Page 30: Privacy Settings

    4. Privacy settings For legal and privacy purpose, some organization and companies do not want to capture and store any face data on the systems. On Face Recognition interface, select setting bottom, turn off the Visitor record function. The software will not record any face data.
  • Page 31: Control Button

    5. Blackbody DON’T TOUCH THE SURFACE WITH HAND OR SHARP OBJECT! Indicator Control Button Power Switch IR Target Surface Power Socket...
  • Page 32 40℃ The blackbody’s temperature is set to and calibrated as default to- each camera, further settings are requiring when setting up the system. Power on and install at the fix position as indicated!
  • Page 33: Troubleshooting

    6. Troubleshooting Common Trouble Possible Cause Solution Connect the network cable of the camera to the PC to check whether the network cable is in good contact. Network is not connected. Run the ping command to check the network connection and whether the device works normally.
  • Page 34 7. Maintenances Use the following procedures to clean the camera body, lens, blackbody and other parts. Camera --Wipe the body clean with soft cloth or eyeglass lens wiper. Lens--First use a lens blower to remove dust and dirt, then remove any remaining dirt by wiping the lens lightly with soft cloth. Never use synthetic cleaners on the camera body or lens! Never use thinners, benzene, synthetic cleaners or water to clean the camera.
  • Page 35: Technical Specifications

    8. Technical Specifications Thermal Camera Detector Type Uncooled IRFPA Microbolometer Effective Pixels 384(H)x288(V) Pixel Size (Pitch) 17µ m Thermal Sensitivity (NETD) 50mK @ F1.0, 30° C Spectral Range 8~14µ m Image Settings Polarity LUT/DVE/Mirror/FCC/3D DNR/Brightness/Contrast/ROI Colour Palettes Black-Hot/White-Hot/Rainbow/Iron-Red (up to 17 modes) Thermal Lens Characteristics Lens Type Fixed...
  • Page 36: Video And Audio

    Video & Audio Compression H.265, H.264, MPEG Frame Rate Main-stream: Thermal: D1@25/30fps ¦ Visible: 20x1080/1280x720@25/30fps Sub-stream: Thermal: CIF@25/30fps ¦ Visible: 1/VGA/640x360/CIF/QCIF/QVGA@25/30FPS Bit Rate Control CBR/VBR Bit Rate Thermal: 100Kbps~6Mbps Visible: Main-Stream: 500Kbps~10Mbps¦ Sub-stream: 100Kbps~6Kbps Region of Interest ON / OFF (8 Zones, Rectangle) Digital Zoom Mirror Supported...
  • Page 37: Temperature Detection

    Temperature Detection Detection Mode Body temperature monitoring Detection Preset Max 16 goals Temperature Alarm Over temperature alarm, Temperature difference alarm ≤ 0.3 ℃ (Emission rate, distance, ambient temperature, etc..) Accuracy ≤30ms Response Time Temperature Measurement -20 ° C ~ 60 ° C (-4° F ~ 140° F) Range Temperature target >5℃, Display absolute temperature value;...
  • Page 38 General Power Supply DC12V/POE (IEEE 802.3af) Power Consumption Max 10W Operating Temperature -30° C~60° C (-22° F~140° F) Storage Conditions 0~ 90% RH Certifications CE /FCC Ingress Protection IP66 Casing Material Metal Dimensions 212× 182× 136mm Net Weight...

Table of Contents