Speco VIP2PTZ12X User Manual page 31

Full hd outdoor 12x ptz ip camera
Table of Contents

Advertisement

Alarm In
This page allows you to configure the input supported by the camera. The Port can be given
as Normally Open or Normally Close state, and their Normal state can be configured.
An input will be inactive as long as its Normal state equals its Current state. The 2 options
for Normal state are NO (Normally Open) and NC (Normally Close). The input is activated
when the Current state changes so that it no longer equals the Normal state.
• • • • Alarm In Port 1 Setting:
Click the Enable alarm in port 1 checkbox to enable the Alarm In port 1.
- Type: The default setting is NO.
* NO: Normally Open
As an example, if the Normal state for a push button connected to an input is Open
circuit, this means that as long as the button is not pushed (and the Current state
remains as Open circuit), the state will be inactive.
* NC: Normally Close
When the button is pushed, the circuit is grounded, the input's state changes to
Grounded circuit and the input will no longer be in its normal state - it will have
become active.
An input on the camera has an Open circuit when disconnected or when there is a
voltage.
- Dwell time: The default setting is 60 seconds. Dwell time means how long time the
alarm input signal hold on as an input signaling source.
Click the Save button to save the settings, or click the Reset button to clear all of the
information you entered without saving it.
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents