CLEARANCES

CLEARANCES TO COMBUSTIBLES
WARNING
Follow these instructions carefully to ensure safe
installation. Failure to follow instructions exactly can
create a fire hazard.
The appliance cannot be installed on a carpet, tile or
other combustible material other than wood flooring. If
installed on carpet or vinyl flooring, the appliance shall
be installed on a metal, wood or noncombustible material
panel extending full width and depth of the appliance.
71" Minimum
Ceiling
6"
Min.
Figure 4 -
Clearances From The Mantel, Ceiling, and
Side Wall
NOTE: When eyebrow canopy is used, minimum clearance
to combustibles is 21/4" maximum out from fireplace front at
71/2" minimum from opening. Figure 4b. When eyebrow is
FP2333
not used, clearances to combustibles is 12" maximum out
BLDV mantel clear
from fireplace front at 13" minimum from opening. Figure 4
20306741
Side of Fire-
place Opening
Figure 4a -
Mantel Clearances
12" Max.
Depth
13" Min.
From Opening
Figure 4b -
Mantel Clearance with Eyebrow Canopy
FP2333
BLDV7 Series Gas Fireplace
FP2334a
1"
2¹⁄₂"
3"
Top View
FP2334a
BLDV side leg clear
12" Max.
13"
Min.
7¹⁄₂"
Min.
1¹⁄₂" Max.
FP2904
mantel w eyebrow
Wall
Combustible
Material Area
1¹⁄₂"
3¹⁄₂"
4¹⁄₂"
5"
6"
Combustible
Breastplate
3/4" Marble
Eyebrow Canopy
2¹⁄₄" Max.
45°
9