Woodburning fireplace
Hide thumbs Also See for BE36:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
This fireplace uses SL300 Series Chimney
2" CLEARANCE TO COMBUSTIBLES AND BUILDING INSULATION FROM CHIMNEY REQUIRED.
NOTICE: DO NOT discard this manual!
Model(s):

WOODBURNING FIREPLACE

Installation and service of this fireplace should be
performed by qualified personnel. Vermont Cast-
ings Group recommends NFI certified profession-
als, or technicians supervised by an
NFI certified professional.
VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15
Installation Manual
Installation and Fireplace Setup
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT overfire. Overfiring will void your
warranty.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BE36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vermont Castings BE36

  • Page 1: Woodburning Fireplace

    For use with solid wood fuel only. als, or technicians supervised by an NFI certified professional. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 2: Table Of Contents

    D. Secure Offset/Return E. Install Ceiling Firestops F. Install Attic Insulation Shield G. Roof Penetration H. Install Chase/Chase Top I. Termination Cap Requirements J. Install Termination Cap VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 3 Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible __________________________ by ______________________on _________ (Builder/Gen. Contractor) (Installer) (Date) 4044-199 • Rev A • 2-18-15 VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 4: Product Specific & Important Safety Information

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 5: Getting Started

    4 ft. Decorative facing (1.22 m) off and trim ground level. Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 6: Design And Installation Considerations

    73 7/8 65 1/2 37 1/4 52 1/4 21 1/2 BE-42 perpendicular wall. 1219 1422 1876 1664 1327 Figure 2.2 Fireplace Locations VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 7: Locating Fireplace & Chimney

    • Below adjacent structure • Insulated exterior chase • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Figure 2.3 Recommended Chimney Locations VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 8: Tools And Supplies Needed

    Report to your dealer any parts damaged in shipment. • Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 9: Framing And Clearances

    7-1/2 in. 7-1/2 in. 14-1/8 in. (191 mm) (191 mm) (359 mm) Model # 23-3/4 11-7/8 BE-36 1041 29-3/4 14-7/8 BE-42 1067 1194 Figure 3.1 Fireplace Dimensions VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 10: Clearances

    1/2 in. (13 mm) to back & sides of appliance 48 in. 1219 mm 0 in. to floor Figure 3.2 Clearances to Combustible Materials VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 11: Construct The Chase

    In cold climates, the walls of the chase should be insulated to the level of the false ceiling as shown in Figure 3.3. This will help reduce heat loss from the home around the fireplace. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 12: Frame The Fireplace

    * If interior of chase will be drywalled, add the thickness to ** Adjust header height for a raised floor under fireplace. Figure 3.5 Framing the Fireplace VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 13: Protective Metal Hearth Strips

    Raised Platform 2 in. 1 in. (25 mm) min. (51 mm) overlap Floor 2 in. (51 mm) Figure 3.7 Protect the Front of an Elevated Platform VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 14: Outside Air Kit (Optional)

    • Secure flex duct with screws or wire ties. Figure 3.9 Outside Air Installation VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 15: Chimney And Termination Requirements

    16.5 ft (5.03 m) min. height/single offset-return 41-1/4 in. 20 ft. (6.10 m) min. height/double offset-return (1048 mm) 90 ft (27.4 m) max. height Effective Height Figure 4.1 Chimney Requirements VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 16: Offsets/Returns

    103 1/2 2629 49 1/4 1251 94 1/2 2400 Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 17: Termination Requirements

    In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap. Figure 4.3 Multiple Chimney Locations VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 18: Chimney Installation

    Attic shield movement Ceiling firestops are required where chimney passes through ceiling or floor Figure 5.1 Typical Chimney System - Guidelines for Chimney System Installation VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 19: Assemble Chimney Sections

    Vertical straight runs of chimney must be supported every 35 ft (10.7 m). Figure 5.2 Assembling Chimney Sections WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 20: Secure Offset/Return

    • Use an attic insulation shield if the ceiling is insulated. The ceiling firestop may then be attached above or below the joists. VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 21: Install Attic Insulation Shield

    If they have been connected correct- Ceiling Firestop Pipe (267 mm) ly, they will not disengage when tested. Figure 5.7 Install Attic Insulation Shield (firestop below ceiling) VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 22: Roof Penetration

    WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. • Caulk all seams to prevent leaks. .018 (26 ga) min. Galvanized Chase Top Figure 5.9 Chase Top Construction VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 23: Termination Cap Requirements

    Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). Figure 5.10 Installing a TR344 Round Termination Cap VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 24 Minimum Height Maximum Chase Top Chase Chimney Pipe Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 5.15 Installing a DTO134/DTO146/DTS134/DTS146 Cap VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 25: Shrouds

    3 in (76 mm) air space from bottom of shroud Chase Top to top of chase. Figure 6.3 Shroud & TR Series cap with no Radiation Shield VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 26: Mailbox Style Shroud

    Base Dimension 686 x 686 Min. Height Min. Opening Width Above Bottom of Termination Cap Min. Opening Width Min. Opening Height Figure 65 Roofed Style Shroud Dimensions VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 27: Finishing

    2 in. (51 mm) Figure 7.2 Decorative Facing VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 28: Hearth Extension, Building And Finishing

    14.3-20.0 0.07-0.05 14 5/8 in. - 20 3/8 in. Marble • Choose finishing materials carefully. Model # BE-36 1321 BE-42 1067 1676 Figure 7.3 Hearth Extension Dimensions VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 29: Hearth Extension 4" Or More Below Fireplace Opening

    Non-combustible Finishing Material Non-combustible Framing Material 1/2 in. Micore Protective Metal Floor or platform or equivalent Hearth Strips insulation Figure 7.5 Raised Hearth Extension Detail VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 30: Fireplace Opening And Hearth Extension Flush With Floor

    Finished 20 in. Min. Figure 7.9 Place Non-combustible Sealant Floor Hearth Extension Micore Noncombustible Material Protective Metal Hearth Strip Figure 7.8 Flush Hearth Extension Side View VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 31: Mantel And Wall Projections

    1 1/2 in./38 mm minimum maximum Measured from top of fireplace opening Non-combustible Decorative Facing such as: Steel, iron, brick, tile, concrete, slate, glass, plasters. Figure 7.10 Mantel Specifications VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 32: Sidewalls/Surrounds

    [305 mm] Fireplace Outside Opening Dimensions Model # BE-36 1041 BE-42 1067 1194 Figure 7.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening) VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 33: Fireplace Setup

    Repack beyond 4 in. (102 mm) insulation from fireplace side. knockout 4 in. (102 mm) Figure 8.1 Gas Line Installation VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 34: Reference Materials

    20-3/4 in. 8 in. CT Series (527 mm) (203 mm) DT Series Outside 4-3/4 in. (121 mm) Diameter Effective Height 10-1/2 in. (267 mm) SL3 Chimney Stabilizer VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 35 (625 mm) (787 mm) 10-1/2 in. (267 mm) RF371 Roof Flashing CB876 Chimney Joint Band 7 3/4 in. 26 in. TR-TVK - Top Vent Kit CT-3A VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 36 TCT375 Terra Cotta Cap 15-5/8 in. (397 mm) ST375 Square Termination Cap 34-3/4 in. (883 mm) 32-1/2 in. (826 mm) TR342 - Round Telescoping Termination Cap VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 37 DTS134/DTS146 DTO134/DTO146 Decorative Caps DTO134 DTO146 22.7 1168 DTS134 21.18 DTS146 21.18 1168 VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 38: Optional Components

    4 in. (102 mm) i.d. 42 in. (1067 mm) LDSCP-M - Corner Post Kit (for custom size) Bifold Glass Doors LDS-BV Decorative Shroud DM1036, DM1042 Catalog # 12.5 15.5 LDS-BV VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...
  • Page 39 Vermont Castings Group 149 Cleveland Drive Paris, Kentucky 40361 www.vermontcastingsgroup.com VCG Royalton Series • BE36/42 • 4044-197 Installation Manual • Rev A • 02/18/15...