ICFDV40 Fireplace Insert

INSERT CLEARANCES

No combustibles (ie: drapes, doors) may be within, or
swing within 36" of the front of the insert.
Side Wall
10" (254 mm)
Minimum
10" (254 mm)
Minimum
Figure 3 -

Mantel Clearances

MANTEL CLEARANCES
NOTE: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
8
14"
(355 mm)
11"
(279 mm)
NOTE: Side clearance to com-
bustibles is 10" (254 mm) from
opening whether it is side wall
FP2992
or mantel legs.
insert clearances
12" (305 mm)
Maximum Depth
14"
(355 mm)
Fireplace Insert
Opening
Figure 4 -
Mantel Clearances
FP2992

HEARTH REQUIREMENTS

The insert must be installed on a noncombustible hearth
extending a minimum of 10" (254 mm) from the fireplace
opening (local codes may require a larger hearth). The
hearth must also extend to both sides of the face.
Finish Wall
12" (305 mm)
FP2993
mantel clearance

CLEARANCES

Noncombustible
Material Required up
to 9" Above Fireplace
Opening
FP2993
20306751