Installation and Operation
Instructions for
Vent-Free Gas Log Sets*
Models UVL18RN, UVL18MN,
UVL24RN, UVL24MN, UVL30RN,
UVL30MN (Natural Gas)
If the information in this manual is not followed exactly, a fire or explosion may result,
causing property damage, injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicin-
ity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
INSTALLER PLEASE NOTE:
DO NOT begin installation of this gas
logset until all instructions have been
read and understood.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
When used without fresh air, vent-free log sets may give off carbon monoxide, an odorless, poisonous gas.
Some people - pregnant women, people with heart or lung disease, anemia, or persons under the influence of
alcohol, and persons at high altitudes are more affected by carbon monoxide than others.
Early signs of carbon monoxide poisoning resemble the flu - headache, dizziness, and/or nausea. If you have these
signs, the heater may not be installed or working properly. GET FRESH AIR AT ONCE! Have the heater serviced
before using it again.
*These logsets are not for exterior use.
UVL Series
W A R N I N G
W A R N I N G
Tested and listed to ANSI Z21.11.2a-2001,
Unvented Heaters, and Z21.60-1996; CGA 2.26-M96
Decorative Gas Appliances for Installation in
Solid-Fuel Burning Fireplaces.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Models UVL18RP, UVL18MP, UVL24RP,
UVL24MP, UVL30RP, UVL30MP
(Propane)
ATTENTION
Installation and service must be per-
formed by a qualified agency, individual,
firm, corporation, or company, experi-
enced in the installation, repair, and
servicing of this type of gas appliance. Do
not modify, alter or tamper with any part
of this heater, control, or logs.
This appliance may be installed in an
aftermarket, permanently located, manu-
factured (mobile) home, where not prohib-
ited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
7412957 2/02 Rev. 5
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVL18RN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vermont Castings UVL18RN

  • Page 1 Installation and Operation Instructions for Vent-Free Gas Log Sets* Models UVL18RN, UVL18MN, Models UVL18RP, UVL18MP, UVL24RP, UVL24RN, UVL24MN, UVL30RN, UVL24MP, UVL30RP, UVL30MP UVL30MN (Natural Gas) (Propane) W A R N I N G If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, injury, or loss of life.
  • Page 2: General Information

    General Information • To check for leaks, always use a soapy water solution or In order to assure a safe and effective installa- a sniffer. Never test by using an open flame. tion, only a qualified service person who is •...
  • Page 3: Installation Requirements

    Front Rear Overall Overall Pressure (w.c.) Manifold Min. Input Max. Input Width Width Depth Height Min. Max. Pressure BTU/hr BTU/hr 18” UVL18RN 17,000 24,000 30” 17” 15” 18” 5.5” 14.0” 3.5” 18” UVL18MN 15,000 24,000 24” UVL24RN 24,500 35,000 Natural 33”...
  • Page 4: Installation Precautions

    • The Vermont Castings, Majestic Products THIS APPLIANCE MUST NOT BE USED WITH warranty will be voided by, and Vermont GLASS DOORS IN A CLOSED POSITION .
  • Page 5: Provide For Adequate Ventilation

    Installation Requirements If your home meets all of the above criteria, you Fresh Air Requirements for must provide additional fresh air for the appliance as Combustion and Ventilation detailed on Page 6. WARNING If your home does not meet the above criteria, follow the procedure below.
  • Page 6 Example: B. Vent the room directly to the outdoors. (Provide one square inch of opening for each 4,000 BTU/hr.) Gas Range 55,000 BTU/hour For further information on ventilation guidelines and Vent-Free LogSet +25,000 BTU/hour sizing specifications, follow the National Fuel Gas Total 80,000 BTU/hour Code/NFPA 54/ANSI Z223.1, Section 5.3.
  • Page 7: Installation Instructions

    Installation Instructions WARNING Do not install this appliance in bedrooms or bathrooms. Do not allow fans to blow directly into the WARNING: Any change to this heater or its fireplace. Avoid any drafts that alter burner flame patterns. controls can be dangerous. WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this gas logset.
  • Page 8: Damper Stop Installation

    The Vermont Castings Majestic Products’ damper stop is designed so the damper can be locked in the closed position, and still allow a vent for the pilot gasses.
  • Page 9 Front View Without Hood With Hood 8” 42” Flat Mantel Noncom- 3¹⁄₂” Min. Shelf bustible Stand-off Material 8” 38¹⁄₂” 4” Stand-off 20” 12” 7¹⁄₂” Seal with 3¹⁄₂” Noncombustible 4” Noncom- Min. Facing Material bustible 4” Hood Material Top View Mantel Trim Finished Wall Material Firebox...
  • Page 10: Gas Line Connection

    Gas Line Connection WARNING Check the gas type. Use only the gas type indicated Connection directly to an unregulated LP tank on the appliance rating plate. If the gas listed on the can cause an explosion. plate is not the type of gas supplied, DO NOT During the initial purging and subsequent INSTALL the logset.
  • Page 11: Fireplace Screen

    UVL18 UVL24 UVL30 LG114 LG112 LG113 Fig. 8 Positioning logs on grate assembly. Fireplace Screen Control Knob To Wall Switch The fireplace screen must be in place when the appliance is operating, and unless other provisions for combustion air are made, the screen must have openings for the introduction of combustion air.
  • Page 12: Flame Appearance

    Operating Instructions The First Firing On completing the gas line connection, a small amount of air will be trapped in the gas line. When you first light the unit with the pilot light, it will take a few minutes to purge the trapped air. Once you have Red Glow purged the gas line, the pilot and burner will light and operate normally.
  • Page 13: For Your Safety Read Before Lighting

    Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- •...
  • Page 14: Troubleshooting

    Troubleshooting Honeywell Valve (UVL-R series) START CHECK • Supply line hooked up Gas supply on • Shutoff valve open • Lockout has engaged. Wait 60 seconds and try again • Piezo screws are tight for good ground Pilot lights with Piezo •...
  • Page 15 Troubleshooting SIT 630 Eurosit Valve (‘M’ Series) With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free service. If you do experience a problem, this guide will help a CERTIFIED SERVICE PERSON in the diagnosis of problems and the corrective action to take. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 16: Inspecting The Venting System

    Normally, all parts can Any safety screen or guard removed for servicing the be ordered through your Vermont Castings Majestic appliances must be replaced before operating the Products distributor or dealer.
  • Page 17 Piezo Ignitor 9a,b Screw 6a,b PILOT 12a,b 13a,b 18a,b 957-2 The Vermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifica- tions, prices and discontinue colors and products at any time, without notice. UVL Series...
  • Page 18: Replacement Parts List

    Replacement Parts List Ref. Description UVL18 UVL24 UVL30 Complete Log Set 20001420 20001421 20001893 Back Log 7583180 7583175 20001892 Right Cross Log 7583177 20001886 Left Cross Log 7583181 7583176 20001889 Front Log 7583178 7583173 20001890 Middle Log 7583179 7583174 20001891 Middle Left Log 20001888 Middle Right Log...
  • Page 19 Accessories The following accessories are available from your Vermont Castings Majestic Products Dealer. If you need additional information beyond what your dealer can supply, contact The Vermont Castings Majestic Products Company, 410 Admiral Blvd, Mississauga, Ontario, Canada L5T 2N6, Attention: Technical Service.
  • Page 20 2020 UVL Series...
  • Page 21 Paragraphs A duration of any implied warranty prescribed by law may not and B, for a part found to The Vermont Castings Majestic apply to you. Similarly, some states do not permit the exclusion Products Company’s satisfaction, after examination, to be...
  • Page 22 The Vermont Castings Majestic Products Company 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com © The Vermont Castings Majestic Products Company 2222 UVL Series...

Table of Contents

Save PDF