Group dealer. Gas Logs Only use Vermont Castings Group components or the war- ranty will be voided and a fire hazard may be created. If you plan to install a gas log, the gas line should be installed before framing the fireplace.
" (76mm) (64mm) (337mm) Electrical Access If elbows are offset to the back of the unit, chase depth will be 22⁵⁄₈” (575 mm). Fig. 1 BC36MH specifications and framing. BC36MH SPECS BC42MH Manufactured Housing Fireplace Rough " (711mm) Opening Depth 11"...
BC36MH, BC42MH Woodburning Fireplace BCMH Parts Identification Flue Collar Top Panel Damper Outer Collar Extension Damper Control Standoffs Outlet Grille (4 provided) Surround Screen Surround Facing Trim Brick Sides and Back Gas Line Access (both sides) Gas Line Access (both sides)
SK84 " " 47Z⁄₂ 46Z⁄₂ Models BC36MH and BC42MH may also be installed into a site-built or modular home when appropriate IRC, FP288 IBC and/or local building codes are followed. In those Fig. 6 Installed lengths of chimney sections. installations, neither an outside air kit nor the SKRS- FMH Radiant Shield/Firestop may be required.
BC36MH, BC42MH Woodburning Fireplace Installation The Ten Foot Rule Major U.S. building codes specify a minimum chimney Install Electrical Connection height above the roof top. The “Ten Foot Rule” is a fire CAUTION: All wiring shall be done by a qualified safety rule and not a draft rule.
Page 8
BC36MH, BC42MH Woodburning Fireplace Positioning, Safety Strips, Chimney Centerline Securing The Fireplace Actual Center- Slide fireplace into position. point Lift the fireplace front slightly and slide the metal safety 7⁷⁄₈” strips under front bottom edge about 1Z⁄₂” (38 mm), (200mm) allowing the remainder to extend in front of firebox.
Page 9
All Vermont Castings Group mobile home approved Installation fireplaces use 6” (159 mm) outside air duct systems. Install the flex duct to connect the fireplace collar on left Planning the Installation side of fireplace and the termination.
Page 10
BC36MH, BC42MH Woodburning Fireplace Air space Clearances Pipe Section Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas) Pipe Rim Lance Pipe 1Z⁄₂” Standoff Z⁄₂” Air Space to Sides Front View Side View FP558MH Radiant Shield/ Firestop Fig. 12 Install pipe, listening for the snap-lock to fasten.
BC36MH, BC42MH Woodburning Fireplace shield. The thimble extension slips into the radiant the ceiling at the ceiling level. For flat ceilings, cut a 14Z⁄ shield and is fastened to the shield with sheet metal ₂” (368 mm) square in the ceiling. For vaulted ceilings, a screws.
Page 12
Since you have preplanned the height of the termination according to the Ten Foot Rule, continue to install pipe The standard Vermont Castings Group RLTSK8 round to the predetermined height. Install chimney sections top can be used to terminate the chimney in a mobile until ONE SECTION (both pipes) extend through the home installation.
Page 13
12” thick. (305 mm) from top of grille opening for circulating 2. Vermont Castings Group - EH2416, K = .458, 1 models. Do not install a mantel face plate less than inch thick required.
Page 14
BC36MH, BC42MH Woodburning Fireplace Face Plate 1 " Ref. *12” from top of grille opening for circulating Combustible materials are permitted within a shaded area models shown in Figure 22 titled **3” from top of grille opening for circulating Minimum Wall Clearances.
Page 15
BC36MH, BC42MH Woodburning Fireplace Minimum Hearth Extension Dimensions Minimum Wall Clearances (for On-Site Construction) WITH WITHOUT Noncombustible Noncombustible Surround Facing Surround Facing Shaded area starts 1/2" away from 4" Brick (Example material) edge of unit. 4" Firebox Seal cracks Opening...
Page 16
BC36MH, BC42MH Woodburning Fireplace Wall Covering Noncombustible 2x4" Header - Decorative Do not notch at Facing standoffs. Seal all cracks between fireplace surround and wall materials with noncombustible material. Noncombustible Decorative Covering Center Door Gap Should be Consistent Top to Bottom...
250°F or greater. Vermont Castings Group fireplaces are designed to BTU input of a gas appliance installed in fireplace accept a 1/2” (13 mm) gas line for installation of an ap- should be rated less than 100,000 BTU/hr.
Page 18
BC36MH, BC42MH Woodburning Fireplace 120VAC Receptacle Junction BLACK GREEN WHITE BLACK BLACK ON OFF ON/OFF Rocker Switch Fig. 29 FK12 wiring. Fan/Blower Replacement Prior to reinstalling the access panel and the hearth If your fireplace has glass doors, it is recommended the...
BC36MH, BC42MH Woodburning Fireplace Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. BC36MH, BC42MH Woodburning Fireplace replacement parts Ref. Description BC36MH BC42MH BC36MH 1. Damper Blade...
Vermont Castings Group approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the Vermont Castings Group warranty. In addition, such action may void the coverage provided by the owner’s insurance.
Limitations and Exclusions 1. No one has authority to add to or vary this limited warranty, or to create for Vermont Castings Group any other obligations of liability in connection with this fireplace and accessory.