Cleaning And Maintenance; Burner, Pilot And Control Compartment; Pilot Flame; Burner Flame - Vermont Castings BLDV300N SC7SB Installation And Operating Instructions Manual

Bldv7 series direct vent gas fireplace
Table of Contents

Advertisement

BLDV7 Series Gas Fireplace
WARNING
Turn off gas before servicing fireplace. It is recommended
that a qualified service technician perform these check-
ups at the beginning of each heating season
BURNER, PILOT AND CONTROL COMPART-
MENT
Keep the control compartment, logs, and burner areas
surrounding the logs clean by vacuuming or brushing at
least twice a year. Make sure the burner porting, pilot air
opening and burner air opening are free of obstructions
at all times.

PILOT FLAME

The flames from the pilot should be visually checked as
soon as the heater is installed and periodically during
normal operation. The pilot flame must always be pres-
ent when the fireplace is in operation. Figure 43. The
pilot flame has three distinct flames, one engulfing the
thermopile, one engulfing the thermocouple or sensor, and
the other reaching to the main burner.
BURNER
Inspect area around the injector. Remove any lint or foreign
material with a brush or vacuum.

BURNER FLAME

The flames from the burner should be visually checked
as soon as the heater is installed and periodically during
normal operation. In normal operation, at full rate, and
after operating for about 15 to 30 minutes, the flame
should be yellow and slightly taller than the rear log.
Figure 44
If the flame is blue and only in the center, turn off unit
and let cool. After unit is cool, remove logs and check to
make sure the back holes in the burner are not covered
with rock wool. If the back holes are clear, add more rock
wool to the center of the burner. Replace logs.
NOTE: The type of installation, vent system
configuration, and wind effects may cause the flame
patterns to vary.
38

CLEANING AND MAINTENANCE

Signature
Command
System Pilot
Figure 43 -
Pilot Flame
FP2453
hooded pilot flames
Figure 44-
Burner Flame Appearance
LG647
BLDV log flames
Sensor
Thermopile
FP2453
LG647
20306741

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents