CLEANING AND MAINTENANCE
Make sure the gas valve knob is in the "OFF" position.
Wait at least five (5) minutes before start -ing maintenance.
VENTING SYSTEM
A qualified agency should examine the venting system
annually.
CLEANING GLASS
Clean the ceramic glass periodically. Condensation will
sometimes form on the glass during a 0 startup. This is
normal for all gas fireplaces and inserts. This condensation
often attracts dust and lint to the surface of the glass. The
initial paint curing of the appliance can also leave a slight
film on the glass. This is a temporary problem.
You should clean the glass after the first two weeks of use.
After that, you should clean the glass no more than two or
three times a season. Use a mild glass cleaner to clean
the door. Do not use abrasive cleaners. They will damage
the glass surface.
PILOT AND BURNER FLAMES
Visually check pilot and burner flames periodically. Refer
to Figure 51 for typical burner flame. Refer to Figure 52
for typical pilot flame.
Figure 51 -
Typical Burner Flame
•
Allow logs to cool completely before
cleaning. Logs reach high temperatures.
LG1166
ICFDV40 log flame
•
Make sure clearances to combustibles
leave enough room for maintenance and
service.
•
Carefully reassemble and reseal insert
properly after any cleaning or servicing.
20306751
Figure 52 -
Typical Pilot Flame
FIREBOX CLEANING
1. Carefully remove log set, and embers from combustion
chamber.
2. Vacuum burner compartment thoroughly.
3. Vacuum any dust off logs.
4. Remove any lint from main burner and pilot.
5. Carefully replace log set, and embers in their correct
positions. Refer to Pages 20 through 21.
6. Replace door.
7. Relight pilot. Refer to Page 25.
8. Turn on main burners.
LG1122
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
ICFDV40 Fireplace Insert
Sensor
Thermopile
FP2453
FP2453
hooded pilot flames
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
DANGER
Un panneau vitré chaud peut
causer des brûlures.
37