PAIR CONTROL SOLENOID VALVE

• Lift and support the fuel tank. ($Page 93)
• Remove the PAIR control solenoid valve cover 1.
• Disconnect the PAIR control solenoid valve lead wire coupler
2.
• Disconnect the PAIR hoses.
• Remove the PAIR control solenoid valve 3.
• Check that air flows through the air inlet port to the air outlet
port.
• If air does not flow out, replace the PAIR control solenoid
valve with a new one.
• Connect the 12 V battery to the PAIR control solenoid valve
terminals and check the air flow.
• If air does not flow out, the solenoid valve is in normal condi-
tion.
• Check the resistance between the terminals of the PAIR con-
trol solenoid valve.
! Resistance: 18 – 22 Ω at 20 – 30 °C (68 – 86 °F)
" 09900-25008: Multi-circuit tester set
% Tester knob indication: Resistance (Ω)
If the resistance is not within the standard range, replace the
PAIR control solenoid valve with a new one.
Installation is in the reverse order of removal.