"C28" (P1655) STV ACTUATOR CIRCUIT MALFUNCTION
DETECTED CONDITION
The operation voltage does not reach the STVA.
ECM does not receive communication signal from
the STVA.
STV ACTUATOR
INSPECTION
Step 1
1) Remove the fuel tank. ($Page 93)
2) Turn the ignition switch OFF.
3) Check the STVA lead wire coupler for loose or poor contacts.
4) Remove the air intake pipe. ($Page 103)
5) Turn the ignition switch ON to check the STVA operation.
(STV operating order: 95% open → Full open → 95% open)
Is the operation OK?
YES
Go to Step 2.
• Loose or poor contacts on the STVA coupler.
NO
• Open or short circuit in the (P/W or Black) and
(B/Lg or Green) wires.
6) After repairing the trouble, clear the DTC using SDS tool.
($Page 39)
B
P
G
W/B
POSSIBLE CAUSE
• STVA malfunction.
• STVA circuit open or short.
• STVA motor malfunction.
B/Lg
P/W
G
B
1
1
VL800K5 ('05-MODEL)
69
ECM
STVA. 1B
STVA. 1A
STVA. 2B
STVA. 2A