"C49" (P1656) PAIR CONTROL SOLENOID VALVE CIRCUIT MALFUNCTION
DETECTED CONDITION
PAIR control solenoid valve voltage is not input to
ECM.
ECM
PAIR
INSPECTION
Step 1
1) Remove the fuel tank. ($Page 93)
2) Turn the ignition switch OFF.
3) Check the PAIR control solenoid valve coupler for loose or
poor contacts.
If OK, then measure the PAIR control solenoid valve resis-
tance.
4) Disconnect the PAIR control solenoid valve coupler.
5) Measure the resistance between terminals.
! PAIR control solenoid valve resistance:
" 09900-25008: Multi-circuit tester set
% Tester knob indication: Resistance (Ω)
Is the resistance OK?
YES
Go to Step 2.
• Loose or poor contacts on the ECM coupler.
NO
• Replace the PAIR control solenoid valve with a
new one.
6) After repairing the trouble, clear the DTC using SDS tool.
($Page 39)
Engine stop
switch
Br/B
O/W
To GP switch
B/R
B
PAIR CONTROL
SOLENOID VALVE
20 – 24 Ω at 20 – 30 °C (68 – 86 °F)
POSSIBLE CAUSE
• PAIR control solenoid valve circuit open or short.
• PAIR control solenoid valve malfunction.
• ECM malfunction.
Side-stand relay
1
1
VL800K5 ('05-MODEL)
83
Ignition
switch