Oil Pump - Suzuki VL800 Supplementary Service Manual

Hide thumbs Also See for VL800:
Table of Contents

Advertisement

10 VL800K5 ('05-MODEL)
ITEM
Crankshaft thrust bearing
thickness
Crankshaft thrust clearance
Crankshaft runout

OIL PUMP

ITEM
Oil pressure (at 60 °C, 140 °F)
CLUTCH
ITEM
Clutch lever play
Clutch release screw
Drive plate thickness
Drive plate claw width
Driven plate distortion
Clutch spring free length
TRANSMISSION
ITEM
Primary reduction ratio
Secondary reduction ratio
Final reduction ratio
Gear ratios
Shift fork to groove clearance
(3.5 – 6.5 kgf/cm², 50 – 92 psi)
No. 1
No. 2
Low
2nd
3rd
4th
Top
No.1
No.2
STANDARD
1.925 – 2.175
(0.0758 – 0.0856)
0.05 – 0.10
(0.002 – 0.004)
----
STANDARD
350 – 600 kPa
at 3 000 r/min.
STANDARD
10 – 15
(0.4 – 0.6)
1/4 turn back
2.92 – 3.08
(0.115 – 0.121)
3.42 – 3.58
(0.135 – 0.141)
15.9 – 16.0
(0.626 – 0.630)
----
49.2
(1.94)
STANDARD
1.690 (71/42)
1.133 (17/15)
3.090 (34/11)
2.461 (32/13)
1.631 (31/19)
1.227 (27/22)
1.000 (25/25)
0.814 (22/27)
0.10 – 0.30
(0.004 – 0.012)
0.10 – 0.30
(0.004 – 0.012)
LIMIT
----
----
0.05
(0.002)
LIMIT
----
Unit: mm (in)
LIMIT
----
----
2.62
(0.103)
3.12
(0.123)
15.1
(0.594)
0.10
(0.004)
46.8
(1.84)
Unit: mm (in) Except ratio
LIMIT
----
----
----
----
----
----
----
----
0.50
(0.020)
0.50
(0.020)

Hide quick links: