Siemens RVS41.813 User Manual page 94

Avs75, avs37, qaa75, qaa78, qaa55 series heat pump controller
Table of Contents

Advertisement

Floor curing function
Floor curing setpoint
manually
Floor curing setpoint
current
Floor curing day current
Floor curing days
complete
Temperature profile
94/258
Siemens Switzerland Ltd
HVAC Products
Line no.
HC1
HC2
HCP
850
1150
1450
851
1151
1451
1455
1456
1457
Off:
Function is deactivated.
Functional heating (Fh) :
The first part of the temperature profile is automatically completed.
Floor curing heating (Bh)
The second part of the temperature profile is handled automatically.
Floor curing heating and functional heating
The entire temperature profile (first and second part) is handled automatically.
Manually
It is not a temperature profile that is completed, but the floor setpoint is controlled
manually. The function is automatically ended after 25 days.
The flow temperature setpoint for the "manual" floor curing function can be set
separately for each heating circuit.
Shows the current flow temperature setpoint of the running floor curing process.
Shows the current day of the running floor curing process.
If the floor curing process is terminated, the days completed are saved and retained
until the function is started the next time.
After a power failure, the plant resumes the floor curing function at the point in time the
power failure occurred.
In automatic operating modes, the controller ensures automatic completion of the
selected temperature profile.
[TVw]
55
50
45
40
35
30
25
20
0
1
5
7
X
Fh
1
User manual RVS61.843, RVS41.813
6 The settings in detail
Operating line
Floor curing function
Off
Functional heating (Fh)
Curing heating (Bh)
Functional/curing heating
Curing heating/functional heating
Manually
Floor curing setpoint manually
Floor curing setpoint current
Floor curing day current
Floor curing days complete
1
5
10
Bh
Fh + Bh
15
18
[Tag ]
25
CE1U2355en_02
28. September 2009