Indication Of Cooling Mode; Adjusting The Room Temperature Setpoint; Occupancy Button - Siemens RVS41.813 User Manual

Avs75, avs37, qaa75, qaa78, qaa55 series heat pump controller
Table of Contents

Advertisement

Indication of cooling mode

(If available)

Adjusting the room temperature setpoint

Occupancy button

78/258
Siemens Switzerland Ltd
HVAC Products
Continuous operation
Continuous operation maintains the room temperature at the selected operating level.
Heating to the Comfort setpoint
Heating to Reduced setpoint
Characteristics of continuous operation:
• Heating with no time program
• Protective functions active
• Automatic summer / winter changeover (ECO functions) and automatic 24-hour
heating limit inactive in the case of continuous operation with Comfort setpoint
Protection
When using Protection, the heating system is off. But it remains protected against frost
(frost protection temperature) provided there is no power failure.
Characteristics of Protection:
• Heating off
• Temperature according to frost protection
• Protective functions active
• Automatic summer / winter changeover (ECO functions) and automatic 24-hour
heating limit active
Cooling mode
Release of cooling mode is indicated by a bar which appears below the
symbol. Cooling mode is active when the bar for heating mode is
hidden. .
Characteristics of cooling mode:
• Cooling mode in accordance with the time program
• Temperature setpoint in accordance with "Comfort setpoint cooling"
• Protective functions active
• Cooling limit depending on the outside temperature
The heating or cooling setpoint is set depending on the active
operating state.
Turn the setting knob to increase or decrease the
Comfort setpoint
.
After each readjustment, wait at least 2 hours, allowing the room temperature to adapt.
If you do not use the rooms for short periods of time, you can press
the presence button to temporarily reduce heating / cooling.
When the rooms are occupied again, press again the occupancy
button.
• The occupancy button is only active in automatic operation
• The current selection is active until the next switching action according to the heating
program takes place
User manual RVS61.843, RVS41.813
5 Handling
or
CE1U2355en_02
28. September 2009