Gas Consumption; Operating The Fire; The Oxysafe Flame Sensing & Flue Blockage Safety System - Valor 639 Owner's Manual

Open decorative gas fire
Hide thumbs Also See for 639:
Table of Contents

Advertisement

OWNER'S GUIDE

GAS CONSUMPTION

Model 639
Has a maximum natural gas input of 6.85kW (Gross)
Has a minimum natural gas input of 2.3kW (Gross)
Model 639 when converted using kit number 0591301
Has a maximum propane gas input of 6.7kW (Gross)
Has a minimum propane gas input of 4.0kW (Gross)

OPERATING THE FIRE

PLEASE NOTE
When operating your fire for the first time, some vapours may be given off which
may cause a slight odour and could possibly set off any smoke alarms in the
immediate vicinity. These vapours are quite normal with new appliances. They are
totally harmless and will disappear after a few hours use.
The Oxysafe flame sensing & flue blockage safety system.
For your safety, this appliance is fitted with a flue blockage safety device that will
shut down the appliance in the event of abnormal flue conditions. This device is
NOT a substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot
flame goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe that senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off
when hot, always wait at least three minutes before attempting to relight.
Page 7