Troubleshooting VR2
ERROR SIGNAL
ERROR INDICATION - REMEDY
1 Lamp - Low battery voltage
Check the condition of the battery. Check the contact between the battery and the
control unit.
2 Lamps - Failure in left drive motor
Check the connection to the left drive motor.
3 Lamps - Short-circuit in left drive motor
Check the drive motor's contacts and cables.
4 Lamps - Failure in right drive motor
Check the connection to the right drive motor.
5 Lamps - Short-circuit in right drive motor
Check the drive motor's contacts and cables.
6 Lamps - Battery charger connected
Disconnect the battery charger.
7 Lamps - Joystick error
Check that the joystick has not been moved when the wheelchair is started
8 Lamps - Control system error
Check the contacts to the output stage.
9 Lamps - Failure in brake circuit
Check the contacts to the magnetic brake.
10 Lamps - High battery voltage
Check the battery and the contacts between the battery and the control unit.
7+5 Lamps - Communication error
A communication error has been indicated.
Check that the cable to the control panel is not damaged and is correctly inserted.
8+2 Lamps - Adjustment device error
An adjustment device error has been indicated.
If the wheelchair is fitted with more than one adjustment device, check which one
is not working. Check the adjustment device cable connections.
61