Table 14 lists the power specifications for the 2109 Model C36 with Model M14

Environmental requirements

Table 15 lists the environmental operating ranges for the 2109 Model C36 with
Model M12 or M14. The requirements for non-operating conditions are also
provided for acceptable storage and transportation environments.
32
IBM TotalStorage SAN Switch: 2109 Model M12 and Model M14 User's Guide
Table 13. Power specifications (continued)
Specification
Heat output (BTU rating)
Maximum inrush current per power cord
Input line protection
Power supply dimensions
Table 14. Power specifications
Specification
Input voltage
Supported power range
Input frequency range
Power supplies (each)
Maximum ac inrush current per power cord
Ride through
Under voltage protection
Table 15. Environmental requirements
Condition
Acceptable range during
operation
Temperature
10°—40°C (50°—104°F)
(See Note)
Humidity
20%—80% RH noncondensing, at
40°C
Altitude
0—3 km (0—10 000 ft) above sea
level
Value
v 64 ports: 1080 watts, 3690 BTU per hour
v 128 ports : 1960 watts, 6700 BTU per
hour
40 amps Peak
Thermal circuit breaker
6.96 cm (2.74 in.) wide, 12.34 cm (4.86 in.)
high, 34.29 cm (13.50 in.) long
Value
A fully loaded switch requires a maximum of
750 Volt-Amps This results in a main current
of 3.2 amps at 240 V ac line voltage or 3.6
amps at 208 V ac line voltage. The rated ac
input range is 180 to 264 V ac.
200–240 V ac, single phase
47–63 Hz
Output voltages: 48 V at 20 amps; 12 V at 4
amps
Maximum output power: 1000 watts
40 amps, peak
The supply outputs remain within specified
regulation for a minimum of 20 msec after
the ac mains are disconnected.
The M14 power supply self-protects from any
input voltage, static or dynamic, from zero
volts to its operating ranges. It recovers to
normal operation upon returning to its
operating range.
Acceptable range during
nonoperation
10°—52°C (50°—126°F)
0%—90% RH noncondensing, at
40°C
0—12 km (0—39 370 ft) above sea
level

Advertisement

Table of Contents
loading

This manual is also suitable for:

Totalstorage 2109 m14

Table of Contents