Q24 Tape Library
Error
Description
Code
D4
UART Error.
Frame overrun or Parity
Error on serial
Interface.
D5
Display Error
Communication to
display failed
D6
Memory Error, Stack
and heap overflow.
D7
Fatal system error
D8
Data base error
D9
No SCSI IC detected
DA
In Library Verify Test
the barcode reader has
read different barcode
data for the same
cartridge label
DB
Warning event!
See section below
DC
I²C Bus Failure
DD
Warning event!
See section below
DE
Warning event!
See section below
DF
Warning event!
See section below
E0
Incompatible magazine
detected
© Copyright QUALSTAR 2014
User Action
Retry operation; after
several occurrences
contact technical support
Retry operation; after
several occurrences
contact technical support
Retry operation; after
several occurrences
contact technical support
Retry operation; after
several occurrences
contact technical support
Retry operation; after
several occurrences
contact technical support
Retry operation; after
several occurrences
contact technical support
Check barcode label on
scratch cartridge and run
Library Verify Test again.
If the error recurs,
contact technical support
Retry operation; after
several occurrences
contact technical support
Check type of lowest left
magazine
Installation and Operations Manual
Critical Component Status
Check library and media changer
controller
Check library controller and OCP
Library controller probably defective.
Library controller probably defective.
Probably a hardware problem, check
library controller
Library controller probably defective.
Probably a hardware problem, check
library controller
SCSI controller probably defective.
Check SCSI controller and library
controller
Failure in I²C bus communication.
Check library controller and connections
to OCP and backplane.
Check OCP.
Check backplane.
Check drive sleds.
Magazine type not supported.
74