Q24 Tape Library 
Error 
Description 
Code 
A0 
Sled range out of 
specification 
A1 
Open Mail Slot 
(Import/Export 
Element) failed 
A3 
Sled motor #2 blocked 
 
(Note: only relevant for 
8U) 
A4 
Cannot find sled #2 
block within the 
expected range 
 
(Note: only relevant for 
8U) 
A5 
Sled home sensor #2 
not found 
 
(Note: only relevant for 
8U) 
A6 
Elevator sensor not 
found 
 
(Note: only relevant for 
8U) 
© Copyright QUALSTAR 2014
User Action 
Run 'Library Verify Test', 
after several occurrences 
contact technical support
Retry operation, after 
several occurrences 
contact technical support
Run 'Library Verify Test', 
after several occurrences 
contact technical support
Run 'Library Verify Test', 
after several occurrences 
contact technical support
Run 'Library Verify Test', 
after several occurrences 
contact technical support
Run 'Wellness Test', after 
several occurrences 
contact technical support
Installation and Operations Manual 
Critical Component Status 
Media changer probably defective. 
Sled motor not connected or defect. 
Media changer controller or distribution 
boards defect. 
Check sled mechanism according stiffness 
in movement. 
Mail Slot release mechanism defect 
Media changer probably defective. 
Sled motor #2 not connected or defect. 
Sled motor #2 voltage too low. 
Sled home sensor #2 defect. 
Sled sensor #2 connecting cable 
damaged. 
Media changer controller or distribution 
boards defect. 
Check top sled mechanism (gears, sheet 
guide locking) according stiffness in 
movement. 
Media changer probably defective. 
Cabling incorrect. 
Check top sled mechanism (gears, sheet 
guide locking). 
Media changer probably defective. 
Media changer controller defect. 
Sled home sensor #2 defect (mechanics, 
electronics). 
Cabling incorrect. 
Media changer probably defective. 
Media changer controller or distribution 
boards defect. 
Elevator sensor defect (mechanics, 
electronics). 
Cabling incorrect. 
Elevator motor not connected or defect. 
Elevator motor voltage to low. 
Check elevator mechanism according 
stiffness in movement. 
71