Parameter Function
Period
Alarm record function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to enable
corresponding period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Click OK button, system goes back to alarm setup interface, please
click save button to exit.
System only memorizes one event during the anti-dither period. The
Anti-dither
value ranges from 0 to 15s.
Relay Out
Enable alarm activation function. You need to select alarm output port
so that system can activate corresponding alarm device when alarm
occurs.
For 6-ch alarm output port device, the 6
+12V output.
System can delay the alarm output for specified time after alarm ende
Alarm
Latch
The value ranges from 10 seconds to 300 seconds.
System auto activates current channel to record once alarm occurs
Record
Channel
(working with alarm activation function). Please note current device
shall be in auto record mode
System can delay the record for specified time after alarm ended. Th
Record
Latch
value ranges from 10s to 300s.
Please draw a circle to enable email function. System can send o
Email
email to alert you when alarm occurs and ends.
After enabled, alarm info will be prompted out on the local output end.
Screen
display
That is to say, the alarm prompt will be displayed beside the channel
name on the local surveillance image.
Tour
Display the selected video in local monitor window. When alarm
occurs, system can begin one-window tour for the activated record
channel. Please set the tour time in the local end.
PTZ
Here you can set PTZ movement when alarm occurs. Such as go to
activation
preset x when there is an alarm.
The PTZ configuration events include preset, tour, and pattern.
Copy
It is a shortcut menu button. You can copy current channel setup to
one or more (all) channels.

8.3.2.1 Detect

By analyzing video image, system will boot video detection alarm when it senses the motion
signal which meets the senility standard that is previously set.