Download Print this page

Zephyr AK7536ASX Use, Care And Installation Manual page 9

Tempest ii series

Advertisement

WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Duct Tape.
Some Ducting Options
Side wall cap
w/ gravity damper
Roof Pitch w/
Flashing & Cap
Soffit or crawl space
Rear Ducting
7
Side wall cap
w/ gravity damper

Advertisement

loading
Need help?

Need help?

Do you have a question about the AK7536ASX and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ak7500asxAk7548asx