Diagnostics
SYMPTOMS
Bin Switch Fails Open
G Model control boards or E Model control boards with
firmware version Rev.2.047 or higher.
The ice machine will not start an ice making cycle
and the display indicates "Full Bin".
The ice machine displays "Full Bin Remove Ice" in
the clean cycle.
E Control Boards with firmware versions prior to
Rev.2.047
The ice machine will not start an ice making cycle
and the display indicates "Curtain Open".
The ice machine will run in the clean cycle.
Bin Switch Fails Closed
When running a "Long Harvest" alert is displayed
and safety limit 2 indicated.
May be off on a safety limit 2.
The harvest cycle continues after ice opens and
closes the ice damper (harvest cycle is 3.5
minutes).
Part Number STH026 8/12