Diagnostics
SYMPTOMS
Bin Switch Fails Open
G Model control boards or E Model control boards with
firmware version Rev.2.047 or higher.
•
The ice machine will not start an ice making cycle
and the display indicates "Full Bin".
•
The ice machine displays "Full Bin Remove Ice" in
the clean cycle.
E Control Boards with firmware versions prior to
Rev.2.047
•
The ice machine will not start an ice making cycle
and the display indicates "Curtain Open".
•
The ice machine will run in the clean cycle.
Bin Switch Fails Closed
•
When running a "Long Harvest" alert is displayed
and safety limit 2 indicated.
•
May be off on a safety limit 2.
•
The harvest cycle continues after ice opens and
closes the ice damper (harvest cycle is 3.5
minutes).
Part Number STH026 8/12