E-Log Display Text
Error Description
T1 Fault
E21
T1 Sensor
T2 Fault
E22
T2 Sensor
T3 Fault
E23
T3 Sensor
T4 Fault
E24
T4 Sensor
Bin Prb Fault
E25
Bin Low Sens
Bin Prb Fault
E26
Bin Med Sens
E27
Bin Prb Fault
Bin Hi Sens
AUCS (Aucs not Present) (Event
AUCS
E28
Log only - No alarm)
USB Comm (Event Log only - No
USB COMM
E29
Alarm)
USB download error (dlnd) Event
E30
USB DNLD
Log only - No alarm)
Safe Mode (Event Log only - No
Safe Mode
E31
alarm)
Detail Event Log Service Definition
Definition
Each thermistor reading is monitored continuously using six second average values. During Pre-chill
a thermistor had a six second average thermistor values fall outside of the valid temperature range.
Each thermistor reading is monitored continuously using six second average values. A
thermistor had a six second average value outside of the valid range for more than 10 continous
minutes
When the AUCS clean option is selected from the menu, the control checks for the presence of the
AUCS board and if the AUCS is not connected it will signal an Event "AUCS". This will be cleared
as soon as the hardware is detected.
USB Communication error, no USB drive in port or defective USB drive
USB Download error related to USB drive or a defective USB drive
Safe mode allows the ice machine to operate for a period of time in the event of a WLP or ITP
sensor failure. The controller allows the machine to operate based on historical information
collected and model data information stored in the controllers memory.