Manitowoc QuietQube Indigo Series Technician's Handbook page 175

Ice machines
Hide thumbs Also See for QuietQube Indigo Series:
Table of Contents

Advertisement

ICE MACHINE DOES NOT CYCLE INTO HARVEST
Will not harvest symptoms
Low ice production
Thick ice in bin
Large sheet of ice on evaporator
Harvest cycle doesn't start
Freeze cycles are longer than published cycle
times
If ice is on the evaporator initiate a manual harvest
cycle by performing the following keystrokes.
Press Menu
Scroll down to Service and press right arrow
Scroll down to Manual Harvest and press right
arrow - A new freeze cycle will start after the
manual harvest cycle is complete.
NOTE: Ice must be off the evaporator before starting
the procedure.
1. Disconnect the ice thickness probe from the
control board, then reboot the control board by
disconnecting and reconnecting line voltage to the
ice machine.
2. Wait six minutes into the freeze cycle (timing
starts when the water pump energizes).
Ice Machine cycles into harvest normally - Perform
steps 1 & 2 on page 173 to test ice thickness
probe and control board.
Ice machine will not cycle into harvest - Perform
steps 1 through 4 on page 173 to test ice thickness
probe and control board.
Part Number STH026 8/12
175

Advertisement

Table of Contents
loading