SYMPTOM #4 QUIETQUBE® MODELS WITH ICVD CONDENSING UNITS
Ice Machine Will Not Harvest - Freeze Cycle Is Normal and Ice Cubes Are Melted After Harvest
START
Back of cubes are melted
at end of harvest cycle?
NO
NO
Ice remains frozen to the
evaporator at the end of the
harvest cycle?
YES
YES
Refer to Symptom
#2 Freeze Cycle
Operation
Analysis Table
Is Ice Machine level?
YES
Is water flow over the evaporator
in the harvest cycle?
NO
Level Ice
NO
Machine
Refer to
YES
Dump Valve
Diagnostics