Product Features; Preinstallation Preparation - Desa VH Series Stove"VICTOR HEARTH" Owner's Operation And Installation Manual

Cast iron stove and b-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

Product Features

OPERATION
This B-vent cast iron stove with burner system
is clean burning and vents vertically. Heat is
generated by both realistic flames and glowing
embers. When used without the blower acces-
sory, the stove with burner system requires
no electricity making it ideal for emergency
backup heat.
PIEzO IGNITOR
This burner system has a piezo ignitor. This
system requires no matches, batteries, or
other sources to light burner system.
PreinstaLLation
PreParation
WARNING: A qualified in-
staller or service person must
install stove and burner system.
Follow all local codes.
CAUTION: This stove with
burner system creates warm air
currents. These currents move
heat to wall surfaces next to
stove. Installing stove next to
vinyl or cloth wall coverings
or operating stove with burner
system where impurities (such
as, but not limited to, tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor
walls or cause odors.
LOCATION AND SPACE
REqUIREMENTS
Determine the safest and most efficient loca-
tion for your DESA B-vent cast iron stove.
Make sure that rafters and wall studs are not
in the way of the venting system. Choose a
location where the heat output is not affected
by drafts, air conditioning ducts, windows or
doors. Figure 2 shows some common loca-
tions. Be aware of all restrictions and precau-
tions before deciding the exact location for
your stove and termination cap.
112127-01C
When deciding the location of your stove and
burner system, follow these rules:
• Do not connect this stove and burner sys-
tem to a chimney flue serving a separate
solid-fuel burning stove or appliance.
• Due to high temperatures, do not locate this
stove in high traffic areas, or near furniture
or draperies.
• Proper clearances must be maintained.
See Figure 3 below and Figure 4, page 6.
• This stove is a freestanding unit designed
to set directly on the floor. If your stove is
to be installed directly on carpeting, vinyl
tile, or any combustible material other than
wood, it must be installed on a metal or
wood panel extending the full width and
depth of the stove. See Figure 5, page 6.
On Wall
with Vertical
Termination
Through Ceiling
Figure 2 - Common Stove Locations
Figure 3 - Clearances for Standard
www.desatech.com
Corner Installation
with Vertical
Termination
Through Ceiling
Ceiling
42"
36"
from
from
Front
Back
Wall
Floor
29"
6
"
Front
Installation
4"
4
"
5