saFety inFormation
Continued
5. You must keep control compartments,
burners and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, etc.
Turn off the gas valve and pilot light before
cleaning stove or burner system.
6. Have venting system inspected annually by
a qualified service person. If needed, have
venting system cleaned or repaired. See
Cleaning and Maintenance, page 27.
7. Do not use any solid fuels (wood, coal,
paper, cardboard, etc.) in this burner
system. Use only the gas type indicated
on burner system nameplate.
8. This appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
9. Do not use stove or burner system if any
part has been exposed to or under water.
Immediately call a qualified service person
to arrange for replacement of the unit.
10. Do not operate burner system if any log is
broken.
11. Do not operate burner system with glass
door removed, cracked or broken.
12. Do not obstruct the flow of combustion
and ventilation air in any way. Provide
adequate clearances around air open-
ings into the combustion chamber along
with adequate accessibility clearance for
servicing and proper operation.
13. Do not install stove with burner system
directly on carpeting, vinyl tile, or any com-
bustible material other than wood. The stove
must set on a metal or wood panel extend-
ing the full width and depth of the stove.
14. This stove must be properly connected
to a vent system. This stove is equipped
with a vent safety shutoff system.

LocaL codes

Install and use stove and burner system with
care. Follow all local codes. In the absence to
local codes, use the current National Fuel Gas
Code ANSI Z223.1/NFPA 54* (USA) or the cur-
rent CSA-B149.1 Installation Code (Canada).
4
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
Cast Iron
Stove Body
Log Set
Vent
Opening
Rear
Cover
Pilot
Assy
Blower with
Adjustment
Knob (Optional
Installation)
Figure 1 - DESA B-Vent Burner System
Shown Installed in Approved DESA
Cast Iron Stove Body Models SCIVFC,
PSCIVFC, VCIS, PVCIS and VH Series
www.desatech.com
1430 Broadway
New York, NY 10018
Batterymarch Park
Quincy, MA 02269
Product
identiFication
Piezo
Ignitor
Cast Iron Stove Body
Grate
Assembly
Only (Oxford™ Model Shown)
LO
IN
OUT
Control Valve
Stove
Front
Burner
Lava
Rock
Glowing
Embers
112127-01C

Advertisement

Table of Contents
loading

Table of Contents