Desa VH Series Stove"VICTOR HEARTH" Owner's Operation And Installation Manual page 19

Cast iron stove and b-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

instaLLation
Continued
3. Check all joints from propane/LP supply
tank or gas meter to equipment shutoff
valve (see Figure 31 for propane/LP or
Figure 32 for natural). Apply noncorrosive
leak test solution to all gas joints. Bubbles
forming show a leak. Correct all leaks at
once.
Equipment
Shutoff
Valve
Figure 30 - Equipment Shutoff Valve
Equipment
Shutoff Valve
Gas Valve
Figure 31 - Checking Gas Joints
for Propane/LP Gas Burner System
(Oxford™ Model Shown)
Gas Valve
Figure 32 - Checking Gas Joints for
Natural Gas Burner System (Oxford™
Model Shown)
112127-01C
PRESSURE TESTING BURNER SYSTEM
GAS CONNECTIONS
1. Open equipment shutoff valve (see
2. Open propane/LP supply tank valve for
3. Make sure control knob of burner system
Open
4. Check all joints from equipment shutoff
Closed
5. Light burner system (see Lighting Instruc-
6. Turn off burner system (see To Turn Off
Propane/
LP Supply
INSTALLING OPTIONAL WALL
Tank
MOUNT SWITCH - GWMS2
1. Connect one terminal of 25 ft. wire for the
2. Route the 25 ft. wire through openings pro-
3. Connect one bare wire end to each of the
Equipment
Shutoff
4. Install the wall switch and cover in the
Valve
Gas
Meter
www.desatech.com
Figure 30).
propane/LP burner system or main gas
valve located on or near gas meter for
natural gas burner system.
is in the OFF position.
valve to thermostat gas valve (see Figure
31 for propane/LP or Figure 32 for natu-
ral). Apply commercial leak test solution
to all gas joints. Bubbles forming show a
leak. Correct all leaks at once.
tions, page 24). Check all other internal
joints for leaks.
Gas to Appliance, page 24).
wall switch to the TPTH terminal on the
valve. Connect remaining wire terminal to
the TH terminal on the valve. Make sure
that the wire terminals are in the positions
on the unit as pictured in Figure 33. If
wires are not connected as shown, the
switch will not work.
vided on the sides of the burner system to a
convenient location to mount your switch.
terminals of the GWMS2 wall switch.
wall.
Figure 33 - Control Valve Terminals
To Control
Switch or
Optional
Accessory
19

Advertisement

Table of Contents
loading

Table of Contents