ventinG instaLLation
Continued
Figures 21 through 23 show other options for
the gas vent. When venting through a side wall
your vent pipe must have the proper tempera-
ture rating (see Figure 23). Manufacturer's
clearances must also be maintained. Consult
the authority having jurisdiction in your area
regarding venting through side wall.
Figure 21 - Vertical Venting Through
Ceiling Using Two 90º Elbows (Oxford™
Model Shown)
Figure 22 - Vertical Venting
Configuration Through Chimney
(Oxford™ Model Shown)
112127-01C
Figure 23 - Venting Through a Side Wall
INSTALLING VENT SYSTEM INTO
CHASE
A chase is a vertical box-like structure built to
enclose venting that runs along the outside
of a building. A chase is not required for such
venting.
NOTICE: Treatment of firestops
and construction of the chase
may vary from building type to
building type. These instruc-
tions are not substitutes for the
requirements of local building
codes. You must follow all local
building codes.
Note: When installing in a chase, you should
insulate the chase as you would the outside
walls of your home. This is especially im-
portant in cold climates. Minimum clearance
between vent pipes and combustible materials
such as insulation is 1".