Linker Error Messages
All messages, except for the warning messages, cause the link
session to end. After you locate and correct a problem, you must
restart the linker.
Messages appear in the list file and are displayed, unless you
direct the list file to CON. If you direct the file to CON, the
error messages are suppressed.
Attempt to access data outside of segment bounds,
possibly bad object module
This usually indicates that a bad object file exists.
Bad numerlC parameter
A numeric value is not given as digits.
Cannot open temporary flle
The linker cannot create the file
VM. TMP
because the disk
directory is full. Insert a new disk. Do not remove the disk that
is to receive the List map file.
Error: dup record too complex
A DUP record in an assembly language module is too complex.
Simplify the DUP record.
Error: fixup offset exceeds field width
An assembly language instruction refers to an address with a
short instruction instead of a long instruction. Edit the assembly
language source and reassemble.
Input flle read error
This usually indicates that a bad object file exists.
Invalld object module
An object module or modules are incorrectly formed or incom-
plete (as when assembly is stopped in the middle).
Symbol defined more than once
The linker found two or more modules that define one symbol
name.