(12) Offset occurs.
Causes
1. Defective cleaning blade.
(13) Image is partly miss-
ing.
Causes
1. Paper damp.
2. Paper creased.
3. Flawed drum.
(14) Fixing is poor.
Causes
1. Wrong paper.
2. Flawed press roller.
Causes
1. Defective cleaning blade.
Replace the process unit.
Causes
1. Paper damp.
2. Paper creased.
3. Flawed drum.
Check the paper storage conditions.
Replace the paper.
Replace the process unit.
Causes
1. Wrong paper.
2. Flawed press roller.
Check if the paper meets specifications.
Replace the press roller (see page 1-6-26).
Check procedures/corrective measures
Check procedures/corrective measures
Check procedures/corrective measures