Lts Series - Inclined Mounting Instructions - Space-Ray LTU80-N5 Installation And Operation Instructions Manual

Space-ray infrared radiant tube heater single stage pull through system (negative pressure) ltu series/lts series
Table of Contents

Advertisement

11.9)

LTS SERIES - INCLINED MOUNTING INSTRUCTIONS

These inclined mounting instructions relate to LTS series heaters (straight tubes) that do not utilize the elbow
accessory. These heaters have been tested and design certified by the CSA for 2"/12" pitch (10º) inclined
mounting of the heater from the control box to the draft inducer assembly as shown in the following diagram.
The purpose of this type mounting is to allow the heater to be mounted in the plane of the roof (particularly in
modern "Butler" type buildings frequently used today). This will typically put the heater out of the way while still
providing the warmth and comfort. The heater can be inclined upwards from the control box to the draft inducer
at a distance of 2 inches up for every linear foot of the heater length. The total rise for each draft inducer is
tabulated in the table below:
TOTAL DRAFT INDUCER HEIGHT ABOVE HORIZONTAL FOR 2"/12" PITCH INSTALLATIONS
MODEL
LTS 40-75
LTS 80-120
LTS 125-130
LTS 140-175
MODEL
LTS 180-250
The heater is subject to all other requirements presented in these Installations Instructions, particularly the
Clearances to Combustibles. If you plan to use this type of installation, order the Space Ray Inclined Mounting
Kit, Part #43238000.
Form #43155010
Mar 09
15 Ft.
20 Ft.
25 Ft.
30"
40"
50"
50 Ft.
55 Ft.
60 Ft.
100"
110"
120"
Tube Length
30 Ft.
35 Ft.
60"
60"
70"
60"
70"
Tube Length
65 Ft.
70 Ft.
130"
140"
-27-
40 Ft.
45 Ft.
50 Ft.
80"
90"
100"
80"
90"
100"
75 Ft.
80 Ft.
150"
160"