Typical Layouts - Pts/Ptu Series - Space-Ray PTS Series Installation And Operation Instructions Manual

Infrared radiant tube heater
Table of Contents

Advertisement

7.0)
TYPICAL LAYOUTS – PTS/PTU SERIES
MODEL
PTS 40
10 Ft.
PTS 50
20 Ft
PTS 60
20 Ft
PTS 75
20 Ft.
PTS 100
30 Ft.
PTS 125
30 Ft
PTS 150
40 Ft.
PTS 175
50 Ft.
PTS 200
50 Ft.
NOTES:
1. In all configurations, the control unit must be connected directly to either a) the 12-radial hole flange of the
10 ft. aluminized steel starting body section (for 10 ft., 20 ft., and 30 ft. systems) or b) the 6-hole flange of
the 10 ft. alumi-therm steel starting body section (for 40 ft., 50 ft., 60 ft., and 70 ft. systems).
2. Joining of two 90º elbows directly together to form a "Z" shape IS NOT permitted.
3. PTS / U 175 - 40 ft length available for special applications.
4. 5 Ft. Body Packages may be utilized on any of these heaters to yield heater lengths from 15 ft. to 70 ft.
5. Any configuration of components not shown in the illustrations may be used except as noted in 1 and 2
above.
EMITTER LENGTH
Min.
Max.
20 Ft.
40 Ft.
40 Ft.
40 Ft.
50 Ft.
60 Ft.
60 Ft.
70 Ft.
70 Ft.
-12-
BODY LENGTH
MODEL
Min.
PTU 40
10 Ft.
PTU 50
10 Ft.
PTU 60
10 Ft.
PTU 75
10 Ft.
PTU 100
15 Ft.
PTU 125
15 Ft.
PTU 150
20 Ft.
PTU 175
25 Ft.
PTU 200
25 Ft.
Max.
10 Ft.
20 Ft.
20 Ft.
20 Ft
25 Ft.
30 Ft.
30 Ft.
35 Ft.
35 Ft.
Form 43343330