Lts Series - Adding Optional Corner Reflector; Lts Series - Attaching Control Box Assembly - Space-Ray LTU80-N5 Installation And Operation Instructions Manual

Space-ray infrared radiant tube heater single stage pull through system (negative pressure) ltu series/lts series
Table of Contents

Advertisement

11.6)

LTS SERIES - ADDING OPTIONAL CORNER REFLECTOR

1. Place the corner reflector over the reflectors of both body sections.
2. Secure by sliding speed clips on the reflector edges. One speed clip is required for each side of reflector.
3. The corner reflector can be used only when the long axis of the heater is level and mounted in a horizontal
position.
11.7)

LTS SERIES - ATTACHING CONTROL BOX ASSEMBLY

1. Attach the control box and gasket to end of tube flange and secure with 1/4-20 locknuts. NOTE: The control
box must be mounted to an aluminized steel body section (24-hole flange) for 40-200 MBtu/hr models, or to
a 10 ft. Alumi-Therm steel body section (6-hole flange) for 225-250 MBtu/hr models, regardless of
configuration used. Failure to attach the control box to the flange end as indicated above will void the
manufacturer's warranty.
2. A 3/8" connector is located on the left side of the control cabinet to provide strain relief for field wiring to
the draft inducer junction box (refer to Section 16.0) on Electrical Connections and Connection Wiring
Diagram for wiring between the control box and the draft inducer.)
3. The control box must be mounted with the perforated fresh air plate on top, facing the ceiling.
Form #43155010
Mar 09
-25-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents