LTS SERIES TYPICAL LAYOUTS

NOTES:
1. In all configurations, the control unit must be connected directly to either a) the 24-hole flange of the 10 ft.
aluminized steel start/end body section (for LTS 40-200 models) or b) the 6-hole flange of the 10 ft. alumi-
therm steel starting body section (for LTS 225 and 250 models). Failure to attach the control box to the 6-
hole flange for LTS 225-250 as indicated above will void the manufacturer's warranty.
2. Joining of two 90º elbows directly together to form a "Z" shape IS NOT permitted.
3. 5 Ft. Body Packages may be utilized on any of these heaters to yield heater lengths from 15 ft. to 80 ft.
4. Any configuration of components not shown in the illustrations may be used except as noted in 1 and 2
above.
MODEL
LTS 40
LTS 50
LTS 60
LTS 75
LTS 80
LTS 90
LTS 100
LTS 110
LTS 120
LTS 125
Form #43155010
Mar 09
EMITTER LENGTH
Min.
Max.
15 Ft.
20 Ft.
15 Ft.
30 Ft.
20 Ft.
30 Ft.
20 Ft.
30 Ft.
30 Ft.
40 Ft.
30 Ft.
40 Ft.
30 Ft.
40 Ft.
30 Ft.
40 Ft.
30 Ft.
40 Ft.
30 Ft.
50 Ft.
MODEL
LTS 130
LTS 140
LTS 150
LTS 160
LTS 175
LTS 180
LTS 200
LTS 225
LTS 250
-19-
EMITTER LENGTH
Min.
Max.
30 Ft.
50 Ft.
40 Ft.
50 Ft.
40 Ft.
50 Ft.
40 Ft.
50 Ft.
40 Ft.
50 Ft.
50 Ft.
80 Ft.
50 Ft.
80 Ft.
50 Ft.
80 Ft.
50 Ft.
80 Ft.