Complete Installation; Check Operation - KitchenAid RANGE HOOD LINER with INTERNAL BLOWER Installation And Use Instructions Manual

36" (91.4 cm) and 48" (121.9 cm) range hood liner with internal blower
Table of Contents

Advertisement

Available languages

Available languages

WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death or electrical shock.
6. Connect ground wire to the ground screw connector.
A. Ground screw connector
B. Ground wire (green or bare)
C. Power supply cable
D. Strain relief
7. Use twist-on connectors and connect black wires together.
8. Use twist-on connectors and connect white wires together.
9. Tighten strain relief securely.
10. Replace terminal box cover. Tighten screw securely.
11. Reconnect power.
B
A
C
D

Complete Installation

1. Connect vent system to hood liner.
2. Seal joints with duct tape.

Check Operation

B
A. Controls
B. Light switch
C. Blower switch
D. Blower speed control switch
1. Move the light switch to the "1" position. The light should
turn on.
2. Move the light switch to the "0" position. The light should
turn off.
3. Move the blower switch to the "1" position. The blower
should turn on.
4. Move the blower speed control switch to vary the blower
speed from low (left) to high (right).
5. Move the blower switch to the "0" position. The blower
should turn off.
6. If range hood does not operate, check that the circuit breaker
has not been tripped or the house fuse blown. Disconnect
power supply and check that the wiring is correct.
7. Reinstall filters. Place back edge of filter into channel at rear
of hood liner and push filter up while pushing tab back. When
filter is in place, release tab. Locking pin will hold filter in
place.
8. Repeat for other filter(s).
9. Install hood enclosure.
A