Install Vent Covers; Complete Installation - KitchenAid KXW2536YSS Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

5. Use UL listed wire connectors and connect black wires (C)
together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.

Install Vent Covers

When using both upper and lower vent covers, push lower cover
down onto hood and lift upper cover to ceiling and install with
2 - 4.2 x 8 mm screws.
NOTE: For vented installations, upper vent cover may be
reversed to hide slots.
C
D
A. Upper vent cover
B. Lower vent cover
C. 4.2 x 8 mm screws
D. Bracket
Secure the bottom of the duct with 2 - 4.2 x 8 mm assembly
screws.

Complete Installation

1. For non-vented (recirculating) installations only, install
charcoal filters over metal vent filter. See the "Range Hood
Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light. See
the "Range Hood Use" section.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
A
B
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kxw2530yss

Table of Contents