MAINTENANCE
Problem
Possible Cause
Locking
Reset the Profl ame DFC board
conditions
The pilot fl ame has gone out
The remote control is not working correctly
The thermostat is disconnected or set too
high
Main burners will
not start
Problem with thermopile circuit
Leak in vent pipe
Improper vent confi guration
Flame lifting
Terminal may be re-circulating fl ue gases
The heater has just been started
Blue Flames
Improper air shutter adjustment
Normal condition: after the appliance warms
Glass fogs up
up the glass will be clear.
The logs or glasses are placed incorrectly
Flames are
burning "dirty" or
Improper air shutter adjustment
sooting
Incorrect rating input
62
TROUBLESHOOTING
Solution
· Turn the system off by pressing the ON/OFF button on the transmitter
· After approximately 2 seconds press the ON/OFF button on the
transmitter again.
· In the manual fl ame control mode, use the down arrow button to reduce
the fl ame to off, indicated by the word OFF displayed on the transmitter
LCD screen.
· Wait approximately 2 seconds and press the up arrow button, the
ignition sequence will start.
· With the transmitter off, move the slider switch on the receiver to the
OFF position.
· Wait approximately 2 seconds and move the receiver slider switch to the
ON position.
· See "Pilot will not remain lit"
· Replace the batteries
· Set the thermostat to a lower temperature
· Check gas line pressure
· Check wiring to thermostat for breaks
· Check for fl ame impingement on thermopile
· Check for leaks in vent connections
· Check vent confi guration with manual
· Check to see if terminal is on correctly
· May need to install high wind termination cap.
· Contact dealer
· Normal during start up: fl ame will yellow as the fi replace heats up
· Adjust air shutter – contact your dealer
**Due to additives in gas, glass may get hazy during operation** Clean as
needed.
· Check log positioning
· Check level of glasses layout
· Increase primary air by opening the air shutter and/or by opening the
vent restrictor
· Check for proper venting and blockage of the vent termination
· See also "Burners will not remain lit"
· Check manifold pressure and clock input rating for over-fi ring
Regency L965E / HZ965E Gas Fireplace