Regency L965E-NG Owners & Installation Manual page 37

L965e / hz965e series
Table of Contents

Advertisement

FOR POWER VENT SYSTEM ONLY
IF NOT USING POWER VENT - SEE CHART ON PAGE 16.
D E
B
L
F
Letter
Canadian Installation
A
B
12 in (30 cm)
C
D
E
F
G
H
3 ft (91 cm) within a height
of 15 ft (4.5 m) above the
meter/regulator assembly
I
3 ft (91 cm)
J
12 in (30 cm)
K
6 ft (1.83 m)
7 ft (2.13 m )t
L
M
1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.
2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code.
* These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier.
t
A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings and it serves both dwellings.
+
Permitted only if verandah, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.
NOTE: Venting terminals shall not be recessed into walls or siding.
Regency L965E / HZ965E Gas Fireplace
B
C
Fixed
Closed
Openable
Openable
B
A
Termination Cap
Air Supply Inlet
Figure 19. Vent Termination Restrictions, refer to Table 1.
Table 1: Vent termination clearances, refer to Figure 19.
1
US Installation
24 in (60 cm)
9 in (23 cm)
12 in (30 cm)*
4 in (10 cm)
4 in (10 cm)
12 in (30 cm)*
4 in (10 cm)
3 ft (91 cm) within a height
of 15 ft (4.5 m) above the
meter/regulator assembly*
3 ft (91 cm)*
9 in (23 cm)
3 ft (91 cm) above if within 10
ft (3 m) horizontally
7 ft (2.13 m) *t
+
19¼ in (49 cm)
H
B
Fixed
Closed
G
J
G
Gas Meter
2
Clearance above grade, verandah, porch, deck, or balcony.
Clearance from window or door that may be opened.
Clearance from permanently closed window (to prevent
condensation).
Vertical clearance to ventilated soffi t located above the terminal,
within a horizontal distance of 2 ft (60 cm) from center line of
terminal.
Clearance to unventilated soffi t.
Clearance to outside corner.
Clearance to inside corner.
Clearance to each side of center line extended above meter/
regulator assembly.
Radial clearance around service regulator vent outlet.
Clearance to non-mechanical air supply inlet to building, or the
combustion air inlet to any other appliance.
Clearance to mechanical air supply inlet.
Clearance above paved sidewalk or paved driveway located on
public property.
Clearance under verandah, porch, deck, or balcony.
INSTALLATION
O
M
K
I
Restriction Zone
(Termination not allowed)
Description
N
G
A
37