Figure 10: Fan and vacuum switch wired.
12. Secure the cord to the Power Vent Assembly with the Strain Relief as shown in Figure 9.
13. Connect the wires to the fan, vacuum switch, and ground according to the wiring diagram in Figure 17. Secure the green ground wire as shown in Figure
9. Route the wires as shown in Figure 10 to prevent them from getting pinched.
14. Align the exhaust defl ector with the exhaust cut out on the bottom of the power vent cover and install, refer to Figure 8, 11 and 12. Ensure that the rubber
vacuum hose does not kink when installed.
15 Secure the cover to the power vent assembly with screws to the left and right sides of the assembly.
16. Remove the protective cover from the PVK Control Box Velcro and secure the power vent control box to the side as shown in Figure 1a.
Figure 13
Regency L965E / HZ965E Gas Fireplace
: Removing Access Cover.
INSTALLATION
Power Vent
Power Vent
Case Cover
Screw
Exhaust
Cut-Out
Figure 11: Install the power vent cover case.
Figure 12: Cover is installed to the power vent
assembly.
Vacuum Switch
Power Vent
Assembly