INSTALLATION
17. When using the 50-1970 Power Vent Kit, there is no need to have the unit set to continuous pilot, connect the 9V clip of the PVK to the 9V clip of the
unit.
a) Remove the Access Cover from inside the fi rebox by removing all ten (10) T-20 screws (see Figure 13).
:
Figure 14
Disconnecting Standing Pilot
Switch.
:
Figure 16
Changing Valve Wiring.
34
b) Disconnect the connection to the Standing Pilot
Switch as shown in Figure 14.
c) Disconnect the TH wires from under the valve
and plug in the two (2) orange wires as shown
in Figure 15.
d) Disconnect the 3 /16" connector from the valve
and connect the two (2) blue wires as shown
in Figure 16.
18. Plug the power cord from the PVK Control Box
into the top outlet of the Electric Box on the
side of the unit as shown in Figure 17.
19. Reinstall the Side Access Cover and continue
with the appliance
Installation steps as shown in the Instruc-
tion Manual.
When installed, the Power Vent Kit, must
be electrically grounded in accordance
with local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.
Periodic examination of venting systems should be done by a qualifi ed agency.
:
Figure 15
Disconnecting TH Wire & Connecting
Orange Wires.
:
Figure 17
Plugging PVK into Electric Box.
Regency L965E / HZ965E Gas Fireplace