Regency L965E-NG Owners & Installation Manual page 28

L965e / hz965e series
Table of Contents

Advertisement

INSTALLATION
Fan Housing
Ground
Strain Relief
Figure 8: Wiring fan.
e) Secure the cover plate to the back of the fan hous-
ing with screws
f) Secure the service wires to the strain relief
f) For wiring options see Figure 9.
8. Attach the 5" Aluminum Flex Vent to the Fireplace
Vent Duct Collar with sheet metal screws or a vent
strap and run the vent to the Fan Housing Vent Duct
Collar. The Fan Housing Vent Duct can be installed
through the rear or the bottom of the Fan Housing
as shown in Figure 10.
IMPORTANT: Maintain a minimum of 2" (51mm)
clearance between the fl ex lines and combustible
materials.
Optional Note: An 8ft (2.4m) 5" Aluminum Flex Vent
is provided. An extra 5" aluminum fl ex run can be
added using a coupling provided by the installer. An
extra 12' in length can be added making the total run
20', which is the maximum allowable.
9. Attach the fan bezel to the fan cut out and secure
the fan bezel to the wall board with screws.
10. Cover the cut out with a fan grille.
When installed, the Power Vent Kit, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your pro-
tection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong
Periodic examination of venting systems should be done by a qualifi ed agency.
28
Cover Plate
5" Aluminum
from this plug.
Flex Vent
Figure 10: Optional install with two (2) heat distribution kits.
8" X 14" grille is required-purchased separately.
Figure 9: Fan wiring options.
Fan Housing
Vent Duct Collar
Fireplace Vent
Duct Collar
3
14
/
" (365mm)
8
Fan Grille
(Not Supplied)
Figure 11: Install fan bezel & grille.
Regency L965E / HZ965E Gas Fireplace
Fan Housing
3
8
/
"
4
(222mm)
Fan Bezel

Hide quick links: