Fireplace
Vent Duct Collar
Hot Air Duct
Opening
Rear of the Unit
Fireplace
Vent Duct
Figure 4: Install the vent duct kit.
3
Min 14
/
"
8
(365mm)
3
Min 8
/
"
4
(222mm)
2"x4" Wall Stud
Figure 6: Minimum Installation Clearances for Fan.
5. Mount and secure the fan housing assembly to the framing members or to the 2x4 wall studs using the mounting brackets and screws provided in the
kit (refer to Figure 7).
Note: The brackets have a guided fl ange which provides the minimum spacing required between the fan housing and 2x4 wall studs or combustible materials.
6. Wire the fan (refer to Figure 8)
a) Feed the 110-120 VAC electrical service wires through the strain relief and through the service hole on the bottom of the fan housing.
b) Secure the service wires to the strain relief.
c) Use the wire nut to join the wires to the service wire.
d) Secure the service ground wire to the ground screw on the cover plate.
Regency L965E / HZ965E Gas Fireplace
TYP 16"
(406mm)
C L
(305mm)
3
1
/
4
(44mm)
Fan Housing
17
(438mm)
Hot Air Duct
1
2
/
"
4
(57mm)
1
18
/
"
4
(464mm)
3
13
/
"
4
(349mm)
2"
1
4
/
"
16
(103mm)
Figure 5: Fan housing overall dimensions.
Ceiling
12"
"
3
1
/
"
4
(44mm)
1
/
"
4
4. With the "F
6: M
INIMUM
Cut a opening for the fan in the wall board; minimum 14" by 8". It cannot
be less than 12" from the ceiling and 1¾" between fan housing to the
closest stud or combustible materials. Do not install in front of the vent.
INSTALLATION
1
2
/
"
4
(57mm)
1
8
/
"
16
(105mm)
2x4 Wall Stud
Fan Housing
Fan Mounting Brackets
Figure 7: Mounting fan housing.
5: F
IGURE
AN HOUSING OVERALL DIMENSIONS
I
C
F
NSTALLATION
LEARANCES FOR
AN
1
5
/
"
16
(129mm)
." and "F
IGURE
."
27