Yellowtec b-line Manual page 52

Digital dual hybrid and phone system for pots / isdn / voip
Table of Contents

Advertisement

T a l k m a s t e r
X T
®
P A G E 5 2
S o f t w a r e
– Connect
Under POTS/ISDN Line you select if you want to signal the status of
Line 1, Line 2 or both lines (Any). If you select Any, the signal is set on
the TTL Pin as soon as one of the lines has the pre-defined status.
– Audio Line: With this function you can signal when a caller is switched
to a certain Audio line. Please select under Audio Line the desired Au-
dio line. Under POTS/ISDN Line you select if you want to signal the
status of Line 1, Line 2 or both lines (Any). If you select Any, the signal
is set on the TTL Pin as soon as one of the lines has been set to the pre-
defined Audio line.
– ON AIR: If you select this function, it is signalled when a caller is
switched to ON AIR. Under POTS/ISDN Line you select if you want to
signal the ON AIR status of Line 1, Line 2 or both lines (Any). If you
select Any, the signal is set on the TTL Pin as soon as one of the lines is
switched to ON AIR.
– PRETALK: If you select this function, it is signalled when a caller is
switched to Pretalk. Under POTS/ISDN Line you select if you want to
signal the Pretalk status of Line 1, Line 2 or both lines (Any). If you se-
lect Any, the signal is set on the TTL Pin as soon as one of the lines is
switched to Pretalk.
– Ringing/Connected State: Toggeling of voltage when a call is coming
in (e.g. for flashing light). When the connection is established, the TTL
Pin is set.
– Called Number:
– Set Information Base Entry: Special function for projects.
– Any System Alarm Pending: This function signals any system alarm.
– Application Alarm Pending: If you enable this function, you can select
under Alarm which Application Alarm you want to signal.
If you select the option Inverted, which is displayed next to the function code,
the inverted signal is transmitted.
Relay
ATTENTION
Please pay attention to the maximum switch current of 200 mA respectively
the maximum switch voltage of 48V per relay output.
!
The following description applies for both configuration windows Relay 1
and Relay 2.

Advertisement

Table of Contents
loading