Hardware Connections For The Flexible Interface Module; Configuration Codes For The Flexible Interface Module - Allen-Bradley 2755-LS7-SB User Manual

Atomscan+ series
Table of Contents

Advertisement

E–4
Application Examples
Flexible Interface Module
Publication 2755-6.9

Hardware Connections for the Flexible Interface Module

The interface box connects to one of the three communication ports
on the flexible interface module with an RS-232 cable. The interface
module requires an SFC1 Protocol Cartridge.
Interface Box
To RS-232 Port
OR
RS-232 Null Modem Cable
(Swap pins 2 and 3.)
SFC1 Protocol Cartridge

Configuration Codes for the Flexible Interface Module

After making the necessary connections, set the reader to the settings
in the table below to allow the reader to communicate with the
flexible interface module.
Description
Baud Rate
9600
Parity
None
Stop Bits
One
Data Bits
8
Reader
Power Supply
RS-232 Cable
Personal
Computer
Menu Setting
Serial Command Setting
<Ka4,0,0,1>