5–26
Configuring Your Reader
Function
Communications
Operations
Code Types
Publication 2755-6.9

Serial Configuration Commands

The table starting below lists the serial configuration commands.
Command
Parameter
Communications
Kf
Protocol
Preamble
Kd
Postamble
Ke
LRC
Kc
Response Timeout
KA
Intercharacter Delay
KB
Host Port
Ka
Auxiliary Port
Ky
Communications
KT
Status Request
Triggering Mode
Kg
End of Read Cycle
Kh
Serial Trigger
Ki
Character
External Trigger Level
Kj
Good Decode Read
Km
Match Code Type
Kn
New Master Pin
Kz
Number of Labels
KL
Operations Status
KV
Request
Narrow Margins
Ko
Code 39
Kp
Codabar
Kq
I 2 of 5
Kr
UPC/EAN
Ks
Code 128
Kt
Code Types Status
KW
Request
Table continued on the next page.
Format
<Kfprotocol,address>
<Kdstatus,ASCII characters>
<Kestatus,ASCII characters>
<Kcstatus>
<KAtimeout setting>
<KBnumber>
<Kabaud,parity,stop bits,data bits>
<Kymode,baud rate,parity,stop bits,data
bits>
<KT?>
<Kgmode,filter time>
<Khmode,time>
<Kicharacter>
<Kjmode>
<Kmnumber>
<Kntype,sequential matching,match start
position,match length,wild card
character,sequence on no
read,sequence on every mismatch>
<Kzstatus>
<KLnumber of labels,multilabel
separator>
<KV?>
<Konarrow margin status,symbology ID
status>
<Kpstatus,check digit status,check digit
output status,large intercharacter
gap,fixed code length status,code
length>
<Kqstatus,start & stop match status,start
& stop output status,large intercharacter
gap,fixed code length status,code
length,check digit type,check digit
output>
<Krstatus,check digit,check digit
output,length 1,length 2>
<Ksstatus,EAN status,supplementals
status,separator status,separator cha.>
<Ktstatus,fixed length,length>
<KW?>